Periodic Maintenance - Exmark Lazer Z Operator's Manual

Air cooled modes
Hide thumbs Also See for Lazer Z:
Table of Contents

Advertisement

POTENTIAL HAZARD
The engine can become very hot.
WHAT CAN HAPPEN
Touching a hot engine can cause severe burns.
HOW TO AVOID THE HAZARD
Allow the engine to cool completely before service or
making repairs around the engine area.

5.1 PERIODIC MAINTENANCE

5.1.1
Check engine oil level:
a)
Stop engine and wait for all moving parts to stop. Make sure unit is on a
level surface.
b)
Check with engine cold.
c)
Clean area around dipstick. Remove dipstick and wipe oil off. Reinsert the
dipstick and push it all the way down into the tube. Remove the dipstick
and read the oil level.
d)
If the oil level is low, wipe off the area around the oil fill cap, remove cap
and fill to the "FULL" mark on the dipstick. Use oil as specified in Engine
Owner's Manual. DO NOT overfill.
IMPORTANT: DO NOT operate the engine with the oil level below the
"LOW" (or "ADD") mark on the dipstick, or over the "FULL" mark.
5.1.2
Check battery charge:
Allowing batteries to stand for an extended period of time without recharging
them will result in reduced performance and service life. To preserve optimum
battery performance and life, recharge batteries in storage when the open
circuit voltage drops to 12.4 volts.
Note: To prevent damage due to freezing, battery should be fully charged
before putting away for winter storage.
a)
Check the voltage of the battery with a digital voltmeter. Locate the voltage
reading of the battery in the table below and charge the battery for the
recommended time interval to bring the charge up to a full charge of 12.6
volts or greater.
IMPORTANT: Make sure the negative battery cables are disconnected
and the battery charger used for charging the battery has an output of 16
volts and 7 amps or less to avoid damaging the battery (see chart below for
recommended charger settings).
Voltage
Reading
12.6 or greater
12.4 – 12.6
12.2 – 12.4
12.0 – 12.2
11.7 – 12.0
11.7 or less
IMPORTANT: For Kohler EFI units: Unplug the harness from the ECU
before performing any welding on the equipment.
WARNING
Service Interval: Daily
Service Interval: Monthly
Percent
Charge
Charger Settings
100%
16 volts/7 amps
75 – 100%
16 volts/7 amps
50 – 75%
16 volts/7 amps
25 – 50%
14.4 volts/4 amps
0 – 25%
14.4 volts/4 amps
0%
14.4 volts/2 amps
- 26 -
Maximum
Charging Interval
No Charging Required
30 Minutes
1 Hour
2 Hours
3 Hours
6 Hours or More

Advertisement

Table of Contents
loading

Table of Contents