Technical Specifications - Soleus Air KY-28U Owner's Manual

Table of Contents

Advertisement

In dehumidifying
mode, no
There is frost on the evaporator
cool air coming out
LCD window
shows "E4"
Noise or vibration
Water is leaking from unit
LCD window
show "E 1"
The water tank is full
The water tank is not installed
correctly
Surface is not level
Surface is not level
Drainage plug is loose
Power supply is unstable
The unit will defrost
automatically
and will return to
operation
afterwards
Empty the water tank
Completely
insert the water
tank
Place unit on a level surface
and away from obstructions
Place unit on a level surface
Make sure the plug of drainage
spout is securely in place and
internal black drain pipe is
plugged
Turn off the unit and wait for
ten minutes before restart.
Call for technical
support if the
"E 1" persists.
TECHNICAL
SPECIFICATIONS
MODEL
COOLING
CAPACITY
HEATING
DEHUMIDIFYING
CAPACITY
POWER
COOLING
DEHUMIDIFYING
AIR FLOW VOLUME
POWER SOURCE
SOUND PRESSURE LEVEL
NET WEIGHT
DIMENSIONS
BODY
PACKAGE
REFRIGERANT
WATER TANK VOLUME
KY-28U
9,000 BTU/H
6000 BTU/H
84 Pints/Day
1100W
1550W
150 CFM
- ll5V60HZ
9.6/13.5
AMP
HEATING/COOLING
52 db
94 LBs
31 x 16 x 15 Inch
33 x 23 x 18 Inch
R22
101 Ounces
NOTE:
1)
2)
3)
The above cooling capacity is measured at ambient telnperamre of DB 86 F, WB 78 F.
Noise level is measured at the point where is 3.28 ft away from the front of the unit, in cooling mode.
Power consumption is measured when fan runs at the highest speed Specifications above are for
reference only. Please see the actual data printed on the nameplate.