Soleus Air KY-320 User Manual

Soleus air portable air conditioner user's manual ky-32u

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Soleus Air KY-320

  • Page 2: Table Of Contents

    INTRODUCTION IMPORTANT SAFEGUARDS PACKAGE CONTAINS: NAMES OF PARTS INSTALLATION BEFORE USE CONTROL PANEL AND LCD DISPLAY CONTROL PANEL FUNCTIONS OPERATION USING CONTROL PANEL OPERATION USING REMOTE CONTROLLER CONDENSATE WATER DRAINAGE MAINTENANCE TROUBLESHOOTING TECHNICAL SPECIFICATIONS DISCLAIMER CONTACT INFORMATION ELECTRIC PRINCIPLE DRAWING WARRANTY TABLE OF CONTENTS...
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing the Soleus Air KY32U portable air-conditioner. This unit is designed for improving living and working comfort by providing cooling, dehumidifying and fan functions only with a minimum installation required. With its whisper quite operation and attractive design, you will enjoy the convenience and comfort that this unit provides for many years to come.
  • Page 4: Names Of Parts

    NAMES OF PARTS control panel upper air outlet handle lower air inlet grille Exhaust Duct Terminal continuous drainage water tank Front View Back View Signal Receptor upper air inlet grill with filter power cord hot air exhaust outlet lower air inlet grille...
  • Page 5: Installation Before Use

    INSTALLATION BEFORE USE Condensate Water Tank Float Lid You must install the water tank float lid before first use of the portable air conditioner following these procedures: Hold the water tank and draw it out slowly. Remove water tank float lid and packing material from the water tank.
  • Page 6 2) Exhaust Duct When you use the unit as an air conditioner, the hot exhaust air must be directed out of the room. The exhaust duct is used to allow the hot air out. DO NOT INSTALL OR USE THE EXHAUST DUCT WHEN THE UNIT IS OPERATED AS A DEHUMIDIFIER OR FAN.
  • Page 7: Control Panel And Lcd Display

    Use screws on the window kit extension if necessary. NOTE: When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements should be taken. CONTROL PANEL AND LCD DISPLAY CONTROL PANEL LCD DISPLAY...
  • Page 8: Control Panel Functions

    When the unit is off, the timer will start the unit in the number of hours set. 6) Sleep Control Activate sleep mode of the air conditioner. Use the Hr button to set the timer from 1 to 7 hours of operation. In the sleep mode, the air conditioner adjusts the temperature according to the time automatically to save power and keep the room comfortable for sleeping.
  • Page 9: Operation Using Control Panel

    OPERATION USING CONTROL PANEL 1) Cooling Operation a) Be sure that the drain tank is properly placed in the unit. b) Install the exhaust duct properly. c) Plug the Power Cord to the power outlet. d) Turn on the unit by pressing the On/Off Button on the control panel. For Manual Mode: Press the Mode Button until the snowflakes and ‘Cool’...
  • Page 10: Operation Using Remote Controller

    NOTE: When the unit is running on fan mode, the exhaust duct is inoperative and is not required. OPERATION USING REMOTE CONTROLLER The remote controller provided with the unit may operate this portable air conditioner. The remote controller uses two - AAA batteries (provided). Install the batteries before using the remote controller.
  • Page 11: Remote Controller

    REMOTE CONTROLLER LCD DISPLAY Set Clock a) Press On/Off key to turn on the remote controller b) Press left side (Hour) or right side (Minute) of the Time Adjustment key until the LCD displays the correct time. c) Press the Transmit key to set time. Cooling Operation a) Press the On/Off key to turn on the remote controller b) Press the Mode key until the LCD displays “COOL”...
  • Page 12 Press the Fan Speed key until the LCD displays the desired fan speed. Press the Transmit key. NOTE: When pressing the Mode Key, the LCD displays “COOL”, “FAN” AND “HEAT”. This KY-32U unit does not have a heating function. 3) Dehumidifying Operation a) Press the On/Off key to turn on the remote controller b) Press Dehumidifying key.
  • Page 13: Condensate Water Drainage

    7) Sleep Mode a) Press the On/Off key to turn on the remote controller. b) Press the Sleep key. “Sleep” will appear on the LCD display. c) Press either /\ of \/ key of the Temperature key until the LCD displays the desired temperature.
  • Page 14: Maintenance

    mode, condensate water does not go to the internal water tank. Condensate is discharged by gravity through the drainage tubing to either an external tank (not provided) or to a condensate water pump device (Optional Item). When the unit is operating on continuous drainage mode, it can operate con- tinuously without periodic stops to empty the water tank.
  • Page 15 maintenance activities. 1) Clean or replace filter If the air filter is blocked with a lot of dust, the airflow volume will reduce. It is recommended to clean the filter once every two weeks or as needed. a) Push down the two tabs on the filter cover and pull outwards to remove the entire filter and cover.
  • Page 16: Troubleshooting

    TROUBLESHOOTING PROBLEM Unit does not operate Unit does not cool room In dehumidifying mode, no cool air coming out LCD window shows “E4” Noise or vibration Water is leaking from unit LCD window show “E1” POSSIBLE CAUSE Unit is unplugged Drain tank is full Water tank not installed correctly Completely insert water tank Air exhaust is clogged...
  • Page 17: Technical Specifications

    MODEL COOLING CAPACITY DEHUMIDIFYING CAPACITY POWER AIR FLOW VOLUME POWER SOURCE SOUND PRESSURE LEVEL NET WEIGHT DIMENSIONS REFRIGERANT WATER TANK VOLUME NOTE: The above cooling capacity is measured at ambient temperature of DB 86 F, WB 78 F. Noise level is measured at the point where is 3.28 ft away from the front of the unit, in cooling mode. Power consumption is measured when fan runs at the highest speed Specifications above are for reference only.
  • Page 18: Electric Principle Drawing

    ELECTRIC PRINCIPLE DRAWING KY-32U...
  • Page 19: Warranty

    WARRANTY Soleus International Inc. warrants the accompanying Soleus Air KY-32U Mobile Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada.
  • Page 20 3. Press RESET button for use If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recom- mendations.

This manual is also suitable for:

Ky-32u

Table of Contents