Section 4: Opecat[on
I
CAUTION
m
. NEVER attempt to power a device requiring more amperage
than generator
or receptacle can supply.
. DO NOT overload the generator: See "Don't Overload
_enerator",
120/240
Volt AC, 30 Amp,
Locking
Use a NEP1A LH4-30
piug with this receptacie.
Connect
a
4-wire
cord set rated for 250VoHtAC
ioads at 30 Amps (or
greater)
(Figure 5).You can use the same 4-wire
cord if you
_ian to run a i20Voit
ioad.
4oWire
Cord Set
/
/
\
(Neutral)
L0_0 _ ° _
Y(Hot)
X(Hot)
NEbIA
L I4-30
/_7
Ground (Green)
This receptacle powers
i20/240VoitAC,
60 Hz, single
phase loads requiring up to 5_550 watts of power
(5.55 kW) at 23.1 Amps for [20Volts or 240Volts.The
oudet
is protected
by a push-to-reset
circuit
breaker.
120 Volt AC, 20 Amp,
Duplex
Use each receptacle
to operate
120VoltAC,
single-phase,
60 Hz electrical
loads requiring
up to 2,400 watts
(2.4 kW)
at 20 Amps of current.
Use cord sets that are rated
for
125 Volt AC loads at 20 Amps (or greater).
G E N E RATO R ADAPTE
R
CORD
SET
The generator is equipped with a 25' generator adapter cord
set designed for a 240Volt, 30Amp grounded neutral circuit
(Figure 7).The generator adapter cord set provides a
convenient supply of emergency power into your dwelling so
that your generator can be operated safely outside.
Each duplex receptacle (Figure 6) is protected
against
overload by a push-to-reset
circuit breaker.
The maximum
load on each oudet
is 20 Amps.The
maximum
total
load on both
yellow
wire
oudets
or black
wire
outHets
is 30 Amps.
NOTE:
Follow
ail safety
precautions
when
connecting
any
extension
cord
or device
to the generator.