Gas Requirements; Commonwealth Of Massachusetts - Samsung DV456EWHDSU/AA User Manual

Gas and electric dryer
Hide thumbs Also See for DV456EWHDSU/AA:
Table of Contents

Advertisement

Available languages

Available languages

GAS REQUIREMENTS
Use only natural or LP (liquid propane)
gases.
THE INSTALLATION
MUST CONFORM
WITH
LOCAL
CODES,
OR IN THE ABSENCE
OF LOCAL
CODES,
WITH THE NATIONAL
FUEL GAS CODE ANSVZ223.1,
LATEST
REVISION
(FOR THE UNITED
STATES), OR WITH THE CAN/CGA-B149
INSTALLATION
CODES
(FOR CANADA).
Gas dryers are equipped
with a burner vent for use with natural gas. If you plan to use your dryer with LP
(liquid propane)
gas, it must be converted
for safe and proper performance
by a qualified service technician.
A 1/2" (1.27 cm) gas supply line is recommended
and must be reduced to connect
to the 3/8" (1 cm) gas
line on your dryer. The National
Fuel Gas Code requires that an accessible,
approved
manual gas shut-off
valve be installed within G" of your dryer.
Gas dryers
installed
in residential
garages
must be raised
18 inches
(46 cm) above
the floor.
Additionally,
a 1/8" (0.3 cm) N.RT. (National Pipe Thread) plugged
tapping,
accessible
for test gauge
connection,
must be installed immediately
upstream
of your dryer's gas supply connection.
Your dryer must be disconnected
from the gas supply
pipe system during any pressure testing
of the
system.
DO NOT reuse old flexible metal gas lines. Flexible gas lines must be design certified by the American
Gas
Association
(CGA in Canada).
[_
ny pipe joint compound
used must be resistant
to the action of any liquefied
petroleum
gas.
As a courtesy,
most local gas utilities will inspect a gas appliance
installation.
GAS IGNITION
- Your dryer uses an automatic
ignition system to ignite the burner.
There is no constant
burning
pilot.
COMMONWEALTH
OF MASSACHUSETTS
INSTALLATION
INSTRUCTIONS
Your dryer must be installed by a licensed plumber
or gas fitter. A "T" handle manual gas valve must be
installed in the gas supply line to your dryer. If a flexible gas connector
is used to install your dryer, the
connector
can be no longer than 3' (36").
*
Gas leaks may occur in your system,
creating a dangerous
situation.
.......
_
Gas leaks may not be detected
by smell alone.
Gas suppliers
recommend
you purchase
and install a UL-approved
gas detector.
Install and use in accordance
with manufacturer's
instructions.
installing
your dryer 13
DV400-03170A
EN HUDSON-PJT
vl.indd
Sec3:13
2012-01-20
N 1:58:28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents