Remote Control, cont'd
= 0 or 1
X3
= 0 through 14, bass adjustment range
X4
(+/-14 dB; 2 dB increment/decrement,
bass in dB = [bass number minus 7] times 2;
default = 7 [0 dB]).
= 0 through 14, treble adjustment range
X5
(+/-14 dB; 2 dB increment/decrement,
treble in dB = [treble number minus 7] times 2;
default = 7 [0 dB]).
= Front panel executive modes
X6
= Controller software version to second decimal place
X7
= A or B, group number
X8
= 1 through 3, preset number
X9
= -12 through +12 (audio gain or attenuation in dB)
X10
= 0 through 12 (audio gain in dB)
X11
= 1 through 12 (audio attenuation in dB)
X12
= 0 through 15, decimal number indicates settings for the
X13
four input and output line level DIP switches. DIP
switch settings are shown in the table below.
DIP
Switch
Group
0
1
1
Input A
Off
Off
2
Input B
Off
Off
3
Output A Off
Off
4
Output B Off
On
RAC 104 • Remote Control
3-4
3 = group B, channel 3
4 = group B, channel 4
0 = off
1 = on
0 = off
1 = executive mode 1
2 = executive mode 2
Group A = channels 1 and 2
Group B = channels 3 and 4
X13
2
3
4
5
6
7
8
Off
Off
Off
Off
Off
Off
On
Off
Off
On
On
On
On
Off
On
On
Off
Off
On
On
Off
Off
On
Off
On
Off
On
Off
Off = -10 dBV (unbalanced, consumer level)
On = +4 dBu (balanced, pro level)
9
10
11
12
13
14
15
On
On
On
On
On
On
On
Off
Off
Off
On
On
On
On
Off
On
On
Off
Off
On
On
On
Off
On
Off
On
Off
On