KitchenAid KXW2530YSS0 Installation Instructions And Use & Care Manual page 9

30" (76.2 cm) and 36" (91.4 cm) wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

4. Run home power supply cable through strain relief, into
terminal box.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect
power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved 1/2"strain relief.
A
B
A. Knockout
B. Terminal box cover
E
A. Home power supply cable
B. UL fisted or CSA approved strain relief
C. Black wires
D. UL fisted wire connectors
E. White wires
F. Green (or bare) and yellow-green
ground wires
5. Use UL listed wire connectors
and connect black wires (C)
together.
6. Use UL listed wire connectors
and connect white wires (E)
together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground
wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical
shock.
7. Connect green (or bare) ground wire from home power supply
to yellow-green
ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.