KitchenAid KHSU265WBA0 Installation Instructions And Use & Care Manual page 6

30" (76.2 cm) and 36" (91.4 cm) slide-out vent hood

Advertisement

Available languages

Available languages

Product Dimensions
9%" (24.8 cm)
5/8"
¾" (1.9cm)
25W' (64.1 cm) - 30" (76.2 cm) modem
31W' (79.4 cm) - 36" (91.4 cm) modem
297/8'' (75.9 cm) - 30" (76.2 cm) model
357/8'' (91.1 cm) - 36" (91.4 cm) modem
4
/,6"(4.0cm)
7.9
18" (45.7 cm) with screen
extended
f
/
Cabinet Dimensions
15" (38.1 cm)
rain.
cmearance
upper cabinet
to countertop
36" (91.4 cm)
base cabinet
height
Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use a 4" (10.2 cm) laundry-type
wall caps.
Use a metal vent only. A rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90 ° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range
hood.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold weather
installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction
of outside temperatures
as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup
air
Local building codes may require the use of makeup air systems
when using ventilation systems with greater than specified
CFM
of air movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
6