h.)Pull o utontheblower motor a nd rotate it90°sothatthe
exhaust outlet i spointing outtheback. Then rotate the
blower motor a round i tsexhaust axis 180 °sotheflatside
oftheblower motor i spointed u p.
NOTE: This istheonly waytheblower motor w illfit
properly intheopening.
B
A. Rotate 90 °
B. Rotate 180 °
C. Flat side of blower motor
i.) Check that the wiring is properly positioned.
j.) Place the power supply cable and grommet through the
center of the outlet hole opening in the mounting panel
and reposition the grommet into its mounting notch.
A
Non-Vented
(recirculating)
Installation Through
the
Soffit/Cabinet
Measure and mark a round vent opening in the soffit using
the method shown for venting through the wall. Measure and
mark the centerline on the soffit above the range hood area.
A
/
I
/'
B
A. Vent cover
B. Centerline
Use the vent cover included with the range hood or other vent
cover as a template to outline an opening for the vent. Use a
saber saw or keyhole saw to cut a round opening for the vent
system.
The range hood can be vented inside through the top of the
cabinet.
6W'
(15.9 crn)
A. Grommet/mounting
notch
k.) Place the blower mounting panel over the exhaust outlet
and mount it onto the hood housing with the 12 mounting
screws. Tighten the screws.
I.) Pull the blower motor out through the opening in the
blower mounting panel and fasten with the 4 blower
mounting screws.
For non-vented (recirculating)
installations, charcoal filters are
necessary. See the "Range Hood Care" section for
instructions
on installing charcoal filters.
The Recirculation
Kit Part Number 4396565 must be used.
5. Install the vent system according to the method needed. Use
caulking to seal the exterior wall or roof opening.
6. Run the wiring through the wall or cabinet according to the
national Electrical Code and all local codes and ordinances.
Use caulking to seal around wire opening.