CARE
IMPORTANT:
Clean the range hood and grease filters frequently
according to the following instructions. Replace grease filters
before operating range hood.
Be sure light is cool before cleaning the range hood.
Exterior Surfaces
Clean the range hood with a mild detergent and soft cloth. To
avoid damage to the exterior surface, do not use abrasive
cleansers or steel-wool
pads
Metal Grease Filters
The filters should be washed frequently. Place filters in
dishwasher or hot, soapy water to clean.
Drain water through edge holes and let each filter dry thoroughly
before replacing it.
To Remove
Metal Grease Filters
1. Pull out on the range hood screen to expose the filters.
2. Using 2 hands, press in the tabs at each end of the metal filter
and pull down to remove it.
3. Repeat Step 2 for each filter.
To Install/Replace
Charcoal
Filters
1. Turn fan and lights off.
2. Remove all 4 metal grease filters. See "Metal Grease Filters"
section.
3. Set metal grease filters aside.
4. Rotate to the left (counterclockwise)
and pull away from the
blower cover and discard filter pack. Repeat for other filter.
A 'ij
A. Filter
5. Place the charcoal filter against the blower cover and rotate
to the right (clockwise) to attach to cover.
6. Replace metal grease filters. See "Metal Grease Filters"
section.
Turn off the range hood and allow the bulb to cool.
Use a 15-watt fluorescent bulb with 30" (76.2 cm) unit and 18-
watt bulb with 36" (91.4 cm) unit.
1. Disconnect
power.
2. Remove the screws from the cover clips at each end of the
light cover. Remove the cover clips and set them aside with
the screws.
\
\
To Replace
Metal Grease Filters
1. Using 2 hands insert the metal filter into the filter openings.
2. Push the metal filter up and press in both tabs on the ends of
the filter. When filter is seated, release the tabs to lock in
place.
3. Repeat steps 1 and 2 for each filter.
Charcoal
Filters - For Non-Vented
(recirculating)
Installations
The charcoal filters are not washable nor reusable.
They should be changed every 6 months in normal use or more
frequently in heavy use. To order new charcoal filters, see the
"Assistance
or Service" section.
A
A. Cover clips and screws
3. Slide the light cover all the way to the right. Lower the left end
of the cover below the support flange and slide it back to the
left to remove the cover.
4. Replace the light bulb.
5. Slide the cover back into position. Reinstall the cover clips
and screws. Tighten the screws.
The charcoal filters capture unpleasant cooking odors.