4=
Run home power supply wiring through 1/2"strain relief into
terminal box.
1=
When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and
install with two 2.9 x 6.5 mm screws.
NOTE: For vented installations
the upper vent cover may be
reversed to hide slots.
A. UL fisted wire connectors
B. White wires
C. Black wires
D. Green (or bare) wire connected
to
yellow-green
wires
E. Home power supply
5. Use UL listed wire connectors
and connect white wires (B)
together.
6. Use UL listed wire connectors
and connect black wires (C)
together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground
wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical
shock.
7. Connect green (or bare) ground wire from home power supply
to the 2 yellow-green
ground wires (D) in terminal box using
UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket
1. For non-vented (recirculating)
installations only, install
charcoal filters over grille on blower housing. See the "Range
Hood Care" section.
2. Install metal filters. See the "Range Hood Care" section.
3. Check the operation of the range hood blower and light. See
the "Range Hood Use" section.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.