Gas Conversions - KitchenAid POWER KBPU182VSS Use & Care Manual

Outdoor built-in power burner
Hide thumbs Also See for POWER KBPU182VSS:
Table of Contents

Advertisement

Available languages

Available languages

2. Remove packing from around burner.
3. Remove plastic bags from grate and film from cover.
4. Reinstall grate.
5. Dispose of/recycle all packaging materials.
6. Go to the "Check and Adjust the Burners" section.
GAS CONVERSIONS
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
Phillips screwdriver
Pipe wrench
Adjustable wrench
10 mm socket and wrench
or 10 mm nut driver
Thin flat-blade screwdriver
Pliers
Pipe thread sealant
certified for LP gas
Parts supplied
Brass connector
Convertible
regulator 4" W.C. Natural, 11" W.C. LP
Natural gas orifices
IMPORTANT:
Gas conversions must be done by a qualified
installer. Before proceeding
with conversion, shut off the gas
supply to the appliance prior to disconnecting
the electrical
power.
This kit is designed for use from sea level up to 2000 ft elevation.
For higher elevations contact KitchenAid at 1-800-422-1230
in
the U.S.A. or call 1-800-607-6777
in Canada.
Explosion Hazard
Use a new CSA International approved
"outdoor"
gas supply
line.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified
person include:
licensed heating
personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Installation
of the regulator
1. Turn off the main gas supply valve.
2. Unplug Power
TM
burner or disconnect
power.
3. Disconnect
20 Ib LP gas fuel tank (if present).
4. Turn off all burner control valves.
15