6.
Use a 10 mm socket and wrench or 10 mm nut driver to
remove the brass orifices from the gas valves.
A
\
7.
8.
9.
B
A. Inner burner
B. Outer burner
Use a 10 mm socket and wrench or 10 mm nut driver to
install the new 2.06 mm (inner burner) and 2.78 mm (outer
burner) brass orifices supplied with this kit.
NOTE: The number 2.06 and 2.78 are stamped on the orifices
for identification.
Replace the burner base. Insure the Iocator pin locks into the
Iocator hole.
A. Locator pin
Replace outer burner top ring, locate with the igniter slot over
the igniter.
A
J
A. Igniter
10. Replace inner burner top ring.
11. Replace the wok ring, locate the tabs to the slots and twist
clockwise to secure.
\
12. Replace burner grate.
Hook up to Natural gas and Leak Test
1. Use pipe wrench to connect certified 1/2"(1.3 cm) gas supply
pipe to inlet side of regulator from Natural gas supply
according to local codes requirements. Use pipe thread
sealant that is certified for use with LP gas at connections
where required. There must be a certified manual shutoff
valve in the gas supply line near the grill for easy access.
2. Turn on the gas supply to the grill.
3. Test all connections
using an approved noncorrosive
leak-
detection solution. Bubbles will show a leak. Correct any leak
found.
Record Conversion
The Power
TM
burner nameplate is located on the right-hand side
panel. With a permanent marker, check the box next to "Natural
gas" and mark through "LP - Propane."
In the last page of the Use and Care Guide, write "Converted to
Natural Gas." Also record the conversion date and the
technician/company
that performed the conversion.
NOTE: Place LP gas parts in plastic parts bag for future use and
keep with pack containing
literature.
........
......... .
:
+
The burners are tested and factory-set
for most efficient
operation. However, variations in gas supply and other conditions
may make minor adjustments
to low flame setting necessary.
It is recommended
that a qualified person make burner
adjustments.
A. 4" (10.2 cm) for outer burner when set to "HI."
B. 3" (7.6 cm) for inner burner when set to HI."
Low Flame Adjustment
If flame goes out on the "LO" setting, the low flame setting must
be adjusted.
1. Turn off the valve and wait until burners are cool.
2. Light Power
TM
burner using information
in the "Outdoor
Power
TM
Burner Use" section.
3. Turn burner to its lowest setting and remove knob.
4. Hold valve stem with pliers and insert a small flat-blade
screwdriver into the shaft.
5. Watch the flame and slowly turn the screwdriver
counterclockwise.
6. Adjust flame to minimum stable flame.
C
A. Valve stem
B. Small flat-blade screwdriver
C. Priers
7. Replace the control knob and turn off the burner.
8. Repeat steps 3 through 7 for each burner if needed.