Kenmore 11092976101 Use And Care Manual page 15

27-inch wide - extra large capacity plus laundry center washer- gas dryer
Table of Contents

Advertisement

Properly leveling your laundry center prevents excessive noise
and vibration.
1. Check the levelness of the laundry center by placing a level
on the top edge of the washer, first side-to-side,
then front-
to-back.
2.
If the laundry center is not level, prop up the front with the
wood block and adjust the feet up or down as necessary.
Remove wood block.
3. Tilt the laundry center forward until the rear of the laundry
center is at least 4 in. (10.2 cm) off the floor. You may hear the
self-adjusting
rear feet click into place. Lower the laundry
center to the floor. Check the levelness of the laundry center
with a level as shown above.
If laundry center will not level, recheck rear leveling legs for
free movement as described in the "Install Leveling Legs"
section. Repeat until the laundry center is level.
NOTE: It may be necessary to level the dryer again after it is
moved into its final position.
4. After the laundry center is in the final location and level, use
an adjustable or open-end wrench to turn the nuts on the
front feet tightly against the washer cabinet.
If the nuts are not tight against the washer cabinet, the
laundry center may vibrate.
1. Remove the red cap from the flexible gas connector.
2.
Remove the 1/2in. NPT adapter from the flexible gas
connector, (it will be necessary to use two adjustable
wrenches).
3.
Install the adapter on the 1/2in. rigid gas supply pipe using
pipe-joint compound.
2
_
::::::@
5 ...............
1. Y2in. rigid gas supply pipe
2. Use pipe joint compound
3. Y2in. NPT adapter
4. Do not use pipe-joint
compound
5. Flexible gas connector
NOTE: For L.R gas connections,
you must use pipe joint
compound
resistant to the action of L.R gas. Do not use
TEFLON _'_ t ape.
4. Attach the flexible gas connector to the 1/2in. NPT adapter.
Do not use pipe-joint compound
for this connection.
There should be a natural loop in the flexible gas connector.
The flexible gas connector must not be twisted, kinked or
attached with any sharp bends.
CORRECT
'_
_
WRONG
Y
IIIn_NG
!
g
5. All connections
must be wrench-tightened.
6. Open the shutoff valve in the supply. The valve is open when
the handle is parallel to the gas pipe.
1. Closed valve
2. Open valve
7. Test all connections
by brushing on an approved non-
corrosive leak-detection
solution. Bubbles will show a leak.
Correct any leak found.
15