Wrench Storage; Miter Gage - Delta 28-150 Instruction Manual

9" bench band saw
Table of Contents

Advertisement

WRENCH STORAGE
The 3mm and 4mm adjustment
wrenches (A) supplied
with your band saw can be conveniently
stored inside
the wheel cover as shown in Fig. 37.
MITER GAGE
A miter gage (A) Fig. 38, is supplied with your band saw.
The miter gage body
(C)can
be adjusted
up to 45
degrees right and left, by loosening lock knob (B), rotat-
ing miter gage body (C) to the desired angle, and tight-
ening lock knob (B).
BLADE CHANGING
To change blades, proceed as follows:
1.
DISCONNECT SAW FROM THE POWER
SOURCE.
2.
Press in door latches (A) Fig. 39, and open door (B)
as shown.
Fig. 37
3.
Loosen two screws (C)Fig. 40, and remove blade
guard (D).
4.
Release tension on the band saw blade by turning
tension knob (E) Fig. 39 counterclockwise.
5.
Remove table alignment screw (F) Fig. 41.
Fig. 38
6.
Slip the blade off both wheels and guide it out
through the slot in the table.
7.
Check the new blade to determine that the teeth will
point down toward
the table when installed. IF NOT,
CAREFULLY TURN BLADE INSIDE OUT.
8.
Place the new blade onto wheels and adjust blade
tension,
blade guides and tracking as described
prev-
iously in this manual.
9.
Replace blade guard, which was removed in STEP 3,
and table
alignment
screw
which
was removed
in
STEP 5.
10. Close door (B) Fig. 39, before operating saw.
Fig. 39
Fig. 4O
Fig. 41