BEFORE
U CALL FOR SER iCE
FRESH
FOOD
OR FREEZER
DOOR
DiFFiCULT
TO OPEN.
• Due to air flow between the compart-
ments, it may be difficult to open the
doors for several seconds after one of
them is closed.
DISPENSER
WiLL
NOT
DISPENSE
WATER OR iCE
(SELECT
MODELS).
• A water fiker_ or the filter bypass plug
must
be in
place
(see
page 13).
° Door is open.
WiLL
NOT
RUN.
° Power cord not plugged in.
• No power at the electrical oudet
• Circuit breaker tripped or house fuse
blown.
• Hain power turned off ("O') (see page
4).
• Touch the ON/OFF pad.
RUNS
TOO
LONG/
TOO
FREQUENTLY°
• Today's energy efficient refrigerators
are larger and require more running
qme to maintain stable temperatures.
• Prolonged door openings.
• Too many door openings.
• Condenser needs cleaning (see page
ug).
• The door not sealing (due to a package
or a container holding door open).
• Warm room temperature.
NoIsY
OPERATION.
• Cabinet not level.
• Weak floon
" See
Normal Operating Sounds (page
21).
ODOR
iN
CABINET.
• Odor producing foods should be cov-
ered or wrapped.
° interior needs cleaning.
WARM
AIR FROM
MACHINE
COMPARTMENT,
• Normal air flow for condenser circula-
tion.
CABINET
VIBRATES,
• Cabinet not level.
° Weak floor.
• Improper installation.
MOISTURE ON INSIDE
CABINET WALLS.
° Can occur during hot, humid weather
with frequent or prolonged door open-
ings.
° Door not closed properly.
EXCESSIVE
MOISTURE
IN OR
AROUND
CLIMATEZONE
TM
DRAWERS,
• Food not wrapped properly.
• Hot, humid weathen
NO
TEMPERATURE
READOUT
iN THE CLIMATEZONE
TM
DRAWER
DISPLAY.
• The Normal Cold setting has been
chosen.
TEMPERATURE
READOUT
IS
NOT WITHIN
TARGET RANGE.
° For
best results, refrigerator
and
freezer controls should be [eft at the
factory settings
(see
page S).
° After drawer openings, the addition of a
new load or changing settings, the
readout may vary.The temperature wiil
recover in a short period of time,
REFRIGERATOR
OR FREEZER
COMPARTMENT
TOO WARM,
• Refrigerator or freezer temperature set
tOO warm,
° Prolonged door openings,
REFRIGERATOR
COMPARTMENT
TOO
COLD.
• Refrigerator temperature set too
cold,
FREEZER NOT FREEZING
PROPERLY.
• Products
with high sugar content
may
not harden completely when frozen (ice
cream, concentrated
juice, etc.)
Do not
store in door.
• Adjust freezer temperature
to a colder
setting.
ICE CUBES EVAPORATE.
° Cold air moving over the ice cubes
causesshrinkage,especiallywith limited
usage, This is normal,
AUTOMATIC
ICE MAKER
NOT
OPERATING,
• Wire lever arm in up (OFF) position.
• Water supply turned off.
• Water pressure too low,
° Freezer too warm,
• Install filter or filter bypass,
FRONT
CABINET
SURFACE
WARM
TO THE TOUCH.
• Special design to limit condensation
during periods of high humidity.
ICE DISPENSER
NOT
OPERATING.
• Ice jam in the dispenser.
° [cemaker not operating.
°
Loci<
switch on (see page 12).
WATER
DISPENSER
NOT
OPERATING,
° Water supply turned off.
• Water pressure too low,
° Loci< switch on (see page 12).
• install fiker or filter bypass,