Section 6 Installation
6.1
General
Have
an
authorized
distributor/dealer
install the
generator set outdoors according to the instructions in
this section.
Do not install this generator set indoors.
The generator set installation must comply with state
and local code requirements.
Use the specifications
provided here only in the initial
planning.
Use the generator set and transfer switch
spec sheets, dimension drawings, and wiring diagrams
for
installation.
Contact
an
authorized
service
distributor/dealer
for the most current information.
6.2
Weight
_1_ WARNING
Unbalanced weight.
Improper
lifting can cause severe
injury or death
and
equipment
damage.
Do not use lifting eyes.
Liftthe generator set using lifting bars
inserted through the lifting holes on
the skid.
The
generator
set
weighs
approximately
186kg
(410 lb.). Use lifting bars inserted through the holes in
the skid to lift the unit. See Figure 6-1 for lifting hole
locations.
6.3
Generator
Set Inspection
Complete a thorough inspection of the generator set.
Check for the following:
1. Inspect the generator set for loose or damaged
parts or wires.
Repair or tighten any loose parts
before installation.
2. Check the engine oil.
Fill, if necessary, with the
recommended
make and grade of oil.
See
Section 3.3.3 for engine oil recommendations.
6.4
Mounting
Install the generator set outdoors.
Maintain a minimum
clearance of 0.9 m (3 ft.) from any building as shown in
Figure 6-1.
Do not install the generator
set where
exhaust gas could accumulate and seep inside or be
drawn into a potentially occupied building.
Mount the
generator set so that the hot exhaust does not blow on
plants or other combustible materials.
See Figure 6-1 for the generator set dimensions
and
fuel
and
electric
inlet locations.
The
drawing
dimensions
are shown in millimeters,
with inches in
brackets.
The generator set is shipped on a plastic mounting pad.
Prepare a flat, level mounting area covered with gravel
or compacted soil. Set the plastic mounting pad directly
on the gravel or compacted soil.
Do not install the
mounting pad directly on the grass.
6.5
Exhaust Requirements
_1_ WARNING
Carbon monoxide.
Can
cause
severe
nausea,
fainting,
or death.
The
exhaust
system
must
be
leakproof and routinely inspected.
Generator
set operation.
Carbon monoxide can cause
severe nausea, fainting, or death. Carbon monoxide is an
odorless, colorless, tasteless, nonirritating gas that can cause
death ifinhaled for even a short time. Avoid breathing exhaust
fumes when working on or near the generator set.
Never
operate the generator set inside a building. Never operate the
generator
set where exhaust gas could seep inside or be
drawn intoa potentially occupied buildingthrough
windows, air
intake vents, or other openings.
The exhaust system is complete for generator
sets
installed outdoors.
Do not install this generator set
indoors.
TP-6195
1/04
Section 6 Installation
25