GE 20 Owner's Manual & Installation Instructions page 19

Side by side refrigerators
Table of Contents

Advertisement

Available languages

Available languages

Performance
Data Sheet
SmartWater Filtration Sgstem-GE®IVlWFCartridge
This sgstem has been tested and certified in filter model GE HWF according to NSF/ANSI Standards/42
and 53 for reduction
of the substances listed below, The
concentration
of the indicated substances
in water entering the sgstem was reduced to a concentration
less then or equal to the permissible limit for water
leaving the sgstem, as specified in NSF/ANSI Standards/42
and 53,* (Safetg factors built in for unmetered
usagel
Standard
No. 42: Aesthetic
effects
Substano
NSF Specifed Challenge
I Average %
Average Product
Max Permissible Product_ NSF Reduction
I NSF Test
Reduction
Average Influent
Concentration
'
Water Concentration
Water Concentration
I Requirements
1Report
0,05 mg/L
N/A
7,833,333 pts/mL
At least I0,000 particles/mL
18,617 pts/mL
N/A
Standard
No. 53: Health
effects
Substance
I
I
Reduction
147,5000 cysts/L
47 MF/L
0.009 mg/L
0.016 mg/L
0.08 mg/L
0.006 mg/L
0.152 mg/L
0.148 mg/L
0.002 mg/L
0.0058 mg/L
0.0061 mg/L
0.222 mg/L
0.015 mg/L
0.015 mg/L
0.218 mg/L
NSF Specified Challenge
Concentration
Minimum
50,000 cysts/L
lOZto 10_ fibers/L; fibers
reater than 10
0.009 mg/L_+ 10%
0.015 mg/L _+10%
0.08 mg/L_+ 10%
0.006 mg/L _+10%
0.15 mg/L _+10%
0.15 mg/L _+10%
0.002 mg/L _+10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.225 mg/L _+10%
0.015 mg/L _+10%
0.015 mg/L _+10%
0.210 mg/L_+ 10%
*Based on the use of Cryptosporidium
parvum
oocysts
Capacity
300 gallons (1,135 liters). Contaminant
reduction
determined
by NSF testing.
Application Guidelines/Water Supply Parameters
Average Product
Max
Water Concentration
Water Concentration
cyst/L
N/A
<1 MF/L
N/A
0.0005 mg/L
0.0005 mg/L
0.001 mg/L
0.0003 mg/L
0.001 mg/L
0.001 mg/L
0.00002 mg/L
0.0004 mg/L
0.0004 mg/L
0.005 mg/L
0.0005 mg/L
0.001 mg/L
0.0009 mg/L
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.002 mg/L
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.002 mg/L
0.002 mg/L
0.075 mg/L
0.005 mg/L
0.003 mg/L
0.07 mg/L
NSF Test
_>99.95%
J-00077721
_>99%
J-00077707
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
J-00077708
J-00077717
J-00077718
J-00082185
J-00077722
J-00077723
J-00077726
J-00077727
J-00077728
J-00077729
J-00082184
J-00077730
J-00077705
Water Pressure
Water Temperature
It is essential that the manufacturer's
recommended
installation, maintenance
and filter replacement requirements
be carried out for the product to perform as advertised,
See Installation
Manual for Warranty information.
Operating
Specifications
• Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
• Temperature: 33-100°F (0.6-38°C)
• Flow rate: 0.5 gpm (1.9 Ipm)
General
InstallationlOpemtionlHaintenance
Requirements
• Flush new cartridge at full flow for 1-1/2 gallons (about three minutes) to purge
trapped aiL
• Replace cartridge when flow becomes too slow,
• Protect from freezing by removing filter cartridge when temperatures
are
expected to drop below 33°F 11°C). D o not install sgstems in areas where
ambient temperatures
meg go above IO0°F or below 40°E Do not install
on o hot water supplg.
Special
Notices
• Installation instructions are included with the product when shipped.
• This drinking water sgstem must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
• Do not use with water that is microbiologicallg
unsafe or of unknown qualitg
without adequate disinfection before or after the sgstem. Systems certified for
cyst reduction may be used on disinfected water that may contain filterable cysts.
•The contaminants
or other substances removed or reduced by this water
treatment system are not necessarily in your wateL
• Check for compliance with the applicable state and local laws and regulations.
• Note that while the testing was performed under standard laboratory conditions,
actual performance
may vary. Systems must be installed and operated in
accordance with manufacturer's
recommended
procedures and guidelines.
• Installation and use MUST comply with all state and local plumbing codes. Do not
install if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi
(552 kPa),you should install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
• Do not install where water hammer conditions may OCCUL If water hammer
conditions exist you must install a water hammer arresteL Contact a plumbing
professional if you are uncertain how to check for this condition.
• Where a backflow prevention device is installed on a water system, a device for
controlling pressure due to thermal expansion must be installed.
Tested and Certified bg NSF International
against ANSI/NSF Standards
42 and 53 in model GE MWF for the reduction
of:
Standard
No. 42: Aesthetic
Effects
Chemical
- Chlorine Taste and Odor
• Mechanical
Filtration
- Particulate
Reduction, Class I
GE
Appliances
Appliance Park
Louisville, KY40225
geapplianceparts.com
Standard No. 53: Health
Effects
• Chemical Reduction
- Atrazine
Reduction
- Endrin Reduction
- Benzene and Carbofuran
Reduction
- 1,4 Dichlorobenzene
and
2,4-D Reduction
- Leadand Lindane Reduction
- Mercurg and Toxaphene Reduction
• Mechanical Filtration
- Cgst and AsbestosReduction
REPLACENENT
ELEMENT
© 2010 GE Compang
PC61278B