2. WINDOW
INSTALLATION
Unit
& Window
Size
1. If your air conditioner cabinet is 20" wide, it will fit window openings 23 7/8" Io39" in width.
Minimum
opening heigi_t is 12 3/4" from bottom of sasb to sill. Removal of botil filler panels
permits installation in windows with a minimum opening width of 20 1/4". This size unit requires
one leveling bracket (Fig. 3).
2, If your air conditioner cabinet is 23 3/4" wide, it will fit window openings 27 5/8" to 39" in widti_.
Minimum opening height is 16" from bottom of sash to silt. Removal of both filler panels permits
installation in windows with a minimum opening width of 24". This size unit requh'es two leveling
brackets (Fig, 4).
1" long
wood screw
1 1/4"
OUTSIDE VIEW
3/8" tbreaded hole
Attach
Filler
Panels
on some
models.,.
1, Attach filler panels to the existing holes in time cabinet using the supplied screws (Fig. 5),
n
rl
o 9--.-i11
D
Top bar
Screws
Bottom bar
Cabinet
Installation
in Normal
Width
Window
1. Open and marl( center line of window. Dependh_g on the size of your unit, attach one leveling
bracket on the center line of the window or one 8" to the right and one 8" to the left of the center
line. Brackets may be attached to window sitl in either direction for maximum support, depending
on the depth of the window sill.
Sill
edge"
Screw
Leveling bolt
Leveling bracket
2. Mark line 1 1/4" from edge of window sill
and fasten leveling bracket with 1" long
wood screws at marl( through larger holes in
bracket (Fig. 6).
3, Screw leveling bolt in 3/8" threaded hole of
leveling bracket and adjust so bolt is 1/4"
below t(_p of window sill (Fig. 7).
4. Repeat steps 2 and 3 for second leveling
bracket, if required.
5. Keeping a firm grip on air conditioner,
carefully center air conditioner in window
opening with the bottom bar sitting behind
window sill. Be sure cabinet maintains an
outward pitch. Air conditioner should slant
slightly downward on the outside as shown