HAMPTON BAY HBLG18H Owner's Manual
HAMPTON BAY HBLG18H Owner's Manual

HAMPTON BAY HBLG18H Owner's Manual

Room air conditioner

Advertisement

Quick Links

+
ROOM AI CONDITIONE
E
W S
Please read the operating instructions and safety precautions
carefully and thoroughly before installing and operating your
room air conditioner.
MANUEL
1"
U
EF
Veuiltez lire attentivement et en entier ce guide d'utifisation
et les mesures de securite ci-incluses avant de preceder &
Hnstallation et au fonctionnement de votre climatiseur.
D'UTiLISATION
A
ET
AIRE ACONDICIONADO
E
Pot favor lea las instrucciones de operaciOn y tas precauciones
de seguridad cuidadosa y totalmente antes de instalar y operar
su acondicionador de aire de ventana.
MODELS,
MODELES,
MODELO:
HBLG18H
Manufactured
by LG Electronics

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HBLG18H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HAMPTON BAY HBLG18H

  • Page 1 Hnstallation et au fonctionnement de votre climatiseur. AIRE ACONDICIONADO Pot favor lea las instrucciones de operaciOn y tas precauciones de seguridad cuidadosa y totalmente antes de instalar y operar su acondicionador de aire de ventana. MODELS, MODELES, MODELO: HBLG18H Manufactured by LG Electronics...
  • Page 2: Read This Manual

    FOR YOUR R£CORDS Stapleyour receipt to t,_is page in easeyou need it later. Writedown the modeland serialnumbers here: Model# Serial# You can find them on a label on the side of eachuniL Dealer's Name DatePurchased READ THIS MANUAL inside you will find many helpful hints on how to use and maintainyour air conditionerproperly.Just a little preventive care on your part can save you a great deal of time and moneyover the life of your air conditioner.
  • Page 3 fety Pre utions To prevent injury to the useror other people and propertydamage,the followinginstructionsmustbe followed, • Incorr_t operation due to ignoring of instruction will cause harm or damage The seriousness is classified by the following indications. " This symbol indicates the possibility of death or serious injury. L,±...
  • Page 4 A3001£,/;, ) 95,:]_284_:(s:P_'_ ..CAUTION) • It may cause an injury. • An oxygen shortage may oocur. • Water may enter the unit and degrade the insulation, tt may cause an electric shock. • Do not use this air conditioner to ,Since the fan rotates at high...
  • Page 5 About the ntrols on the Air nditioner The controls will look like one of the following. • WARNING To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance. • CAUTION When the air conditioner has been performing its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again.
  • Page 6: Air Direction

    A2001£,/;, ) 95,;]_284_:(s:Pt_ ..Additional controls and important information. Ventilation The ventilationlever mustbe in the CLOSEposition in order to maintainthe best cooling conditions. When fresh air is necessaryin the room,set the ventilationleverto theOPEN position. The damperis openedand room air is drawnout. Part (_1 NOTE: Before usingthe ventilationfeature, "_...
  • Page 7 A200SL,/;, ) 95,:]_284_:(s:Pt_ ..How to Connect a Drain Hose A drain hole is providedat the rearof the air conditionerunit, Fig. 1 Select a drain methodaccordingto the following. 1 Removethe hole rubberfrom the base@an,(for some models) ,DRAIN RiPE 2. Connecta drain hoseof %°"insidediameterto the drain pipe DRAIN HOSE as shownin Fig.
  • Page 8: Air Deflector

    A:}00]£,/;, ) 95,:]_28<_:(s:P_'_ ..Features and InMallation Learning parts name prior to installation will heip you understand the installation procedure. 1, CABINET 7 AIR FILTER 2. HORIZONTAL AIR DEFLECTOR 8, CONTROL BOARD (VERTICAL LOUVER) 9 POWER CORD 3. VERTICAL AIR DEFLECTOR 10.
  • Page 9: How To Install The Unit

    How to Install the Unit INSIDE OUTSIDE FENCE AWNING FOAM H EAT 1/4 Bubble COOLED 1. To avoidvibration and noise, make sure the unit is installedsecurelyand firmJy. 2 Installthe unit wherethe sunlight does not shinedirectlyon the unit. If the unit receivesdirect sunlight,build an awningto shadethe cabinet. 3.
  • Page 10: Installationkits Contents

    A200SL,/;, ) 95,:]_284_t(s:Pt_ ..Window NOTE: All supporting parts should be secured to firm wood, masonry, or metal VV/NDOW REQUIREMENTS 1 This unit is designed for installation in standard double hung windows with actual opening widths from 26" to 41" The top and bottom window sashes must -Less open sufficiently to altow a dear vertical...
  • Page 11: Suggested Tool Requirements

    A2001£,/;, ) 95,:]_284_;(s:Pt_ ..Suggested Tool Requirements SCREWDRIVER(+,-), RULER, KNIFE, HAMMER, PENCIL, LEVEL PREPA RATION OF CHASSIS Shipping screws 1 Remove the screws which fasten the cabinet at both sides and at the back. 2. Slide the unit out from the cabinet by gripping the base pan handle and pulling: forward while bracingthe cabinet.
  • Page 12: Cabinet Installation

    Cabinet Installation 1 Open the window. Mark a tine on the center of the win_w stool between the side window stop motding& Bracket Loosety attach the sill bracket to the suppott Bolt Look nut bracket using the carriage bolt and the Io,sk Carfia le"...
  • Page 13 A2001£,/;, ) 95,:]_284_;(s:Pt_ ..5_ Pull each Frame curtain fulty to each window sash track, and pull the bottom window sash down behind the Top retainer bar until it meets, 6, A_ach each Frame curtain the window sash by using screws (Type C,) (See Fig, 10) Fig.
  • Page 14: Electrical Data

    A:}00]£,/;, ) 95,:]_284_:(s:P_'_ ..Electrical Data Line Cord Plug Use Walt Receptacle Power Supply Use 20 AMP_ time delay fuse or circuit " _ding prong breaker , rooo0rouoo,o0 ,o0 r c% ePe 0A:W AC ° Power supply cord with NOTE : Numinum house wiring may pose special problems. Consult a quatified electrician. •...
  • Page 15: Normal Operating

    A20O]£,/;, £ ) 95,:]_284_:(s:Pt_ ..1!£ Troubleshooting Tips Save time and money[ Review the chart below first and you may not need to call for service. Normal Operating • You may'hear a pinging noisecaused by water being picked up and thrown against the condenser on rainy days or when the humidityis high,This design feature helpsremove moistureand improve efficiency •...

Table of Contents