Installation
Instructions
CONNECTING THE DRYER TO
HOUSE VENT (CONT.)
• Never
install flexible
metal duct in walls, ceilings,
floors or odler
enclosed
spaces.
• Total lengdl
of flexible
metal duct should
not
exceed
8 feet (2.4 m).
• Avoid resting
tlle duct on sharp
objects.
• For best diTing performance:
1. Slide one end of the duct over the clodles
dryer outlet
pipe.
2. Secure
the duct witll a clamp.
3. Witll the dryer in its permanent
position,
extend
the duct to its fldl lengdl.
Allow 2" of
duct to overlap
tlle exhaust
pipe. Cut off and
remove
excess duct. Keep tl_e duct as straight
as possible
for maximum
airflow.
4. Secure
the duct to the exhaust
pipe with
the odler
clamp.
EXHAUST
DIRECTION
All (liTers are shipped set up for rear exhausting.
On elecuic d_yers, exhausting can be on the cabinet fight
or left side, or through the dryer bottom. G;ts dryeis can
exhaust on the cabinet fight side or the d_yer bottom. To
change exhaust direction you will need Exhaust Kit Pub.
No. 14-A018 and a rigid metal 4" 90-degree elbow. The kit
is available ttuough your GE remileL Follow the
insmlcdons
supplied with the kit.
Same as
EXHAUST DUCT LOCATING
other side
DIMENSIONS
5 7/8"
115cm)
135/16"
• .
(34cm)
4 3/8"
(11cm)
3 3/4"
3 3/4" (9.5 cm)
EXHAUST
DUCTING
LENGTH
The exhaust
system should
be inspected
and cleaned
a
minimum
of eve U year widl nomml
usage. The more tile
d_yer is used, tlle more
often you should
check tile exhaust
system and vent hood for proper
operation.
• DO NOT assemble the duct work with fasteners that
exmnd into the duct. They will serve as collection points
for lint.
• Insulation - Ductwork which runs through an unheamd
area or is near an air conditioning
duct should be
insulated to reduce condensation
and lint buildup.
MAXIMUM LENGTH
of 4"(10.2cm)Dia.RIGID METAL DUCT
PREFERRED VENTHOODTYPE
4" (10.2cm)
Louvered
Number
of 90°
.
2,5"
_.
L
era) I_
0
60" (18,28m)
48" (14,63m)
1
52" (15,84m)
40" (12,19m)
2
44" {13,41m)
32" {9,75m)
3
32" (9.75m)
24" (7.31m)
4
28" (8.53m)
16" (4.87m)
INSTALLMALE FITTINGS IN CORRECT DIRECTION
GAS SUPPLY REQUIREMENTS
Replace brass connecting
pipe that is not plastic-coated.
Stainless smel or plasfic-coamd brass MUST be used.
WARNING:
Neve,','e.se
old flexible
connectors.
The
use of old flexible
connectors
can cause
gas leaks
and
personal
injm3_ Always
use NEW flexible
connectors
\allen
installing
a gas appliance.
°
Installation MUST conform wifll local codes, or in the
absence of local codes, with the National Fuel Gas
(]ode, ANSI Z223.1 (lamst edition) or in Canada, the
current CAN/CGA B149.
The gas supply line should
be of i/2"
(:l.27 cm) rigid
pipe.
If codes allow, flexible metal robing may be used
m connect your diyer m the gas supply line. The
robing MUST be consmlcmd
of stainless smel or
plasfic-coamd brass.
The gas supply line MUST have an indMdual stmtoff
valve.
°
A 1/8"
(0.32 cm) NPT plugged
tapping,
accessible
for
rest gauge connection,
MUST be installed
immediately
upsUeam
of the gas supply comlecfion
to the d_yeL
The dryer MUST be discomlecmd
flom die gas supply
piping sysmm during any pressure resting of the gas
supply piping sysmm at rest pressures in excess of 1/2
psig (3.45 kPa).
The d_yer MUST be isolamd flom die gas supply piping
system
during any pressure resting of the gas supply
piping system at test pressures equal to or less than
1/2 psig (3.45 kPa).
13