STARTING AND STOPPING
,WARNING
• Do not use pressurized starting fluids.
• Vapors are flammable.
CAUTION:
Some engines may be equipped with OIL
GARD_e. The OIL GARDc<_is intended to warn the
operator that the engine is low on oil. Always check oil
level before starting. Engine damage may occur if the oil
level is not properly maintained and will void warranty
coverage. If the engine will not start, has stopped running
and/or a light flickers in the stop switch, add oil (see
instructions).
REWIND (MANUAL)
STARTER
TO START ENGINE
OIL
LEVEL
[1]
Check oil level (see p. 7).
POSITION
Fuel shut-off
Choke
[2]
Turn fuel shut-off valve (if equipped) 1/4 turn
to OPEN.
[3]
Push choke lever to CHOKE position.
[4]
Move
throttle
(if
equipped)
to FAST.
Operate engine with
throttle in FAST.
[5]
Push rocker switch
(if equipped) to ON.
,WARNING
[6]
Grasp
rope handle.
Pull slowly
until
resistance is felt, then pull rapidly to start
engine and avoid kickback.
[7]
Let engine warm up.
If
choke
equipped:
Slowly adjust toward RUN
position. Wait until engine
runs
smoothly
before
each choke adjustment.
TO STOP ENGINE
CAUTION:
Do not stop
engine by moving choke
control
to
CHOKE.
Backfire, fire or engine
damage could occur.
)
[1]
Move throttle (if equipped)
to SLOW, then to STOR
[2]
Push rocker switch
(if
equipped)
to
OFF.
Fuel shut-off
[3]
Close fuel shut-off
valve (if equipped).