SafetyIssues
GroundFault Circuit InterrupterProtection
This product must be properly grounded. This electric
pressure washer is equipped with a ground fault circuit
interrupter (GFCI).The device will disconnect both power
conductors to the load circuit in the event of an interruption
in either or both supply circuit power conductors. If a
malfunction or breakdown occurs, the GFCIprovides
protection.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordancewith all local
codes and ordinances. Readthe instructions on the plug for
use or see Before Starting Pressure Washer.
AutomaticShut-Off
The pressure washer is equipped with a sensor that will
detect that high pressure water flow has stopped when
releasing or locking the spray gun trigger. The sensor will
cause the motor to shut off for as long as the spray gun
trigger is releasedor locked.
Motor Overload
The electric motor in this pressure washer is equipped with
an overload protection device. This device will automatically
shut off the motor if the motor overheats or draws excessive
current. After a period of time, the device will reset and the
pressure washer can resume normal operation.
ExtensionCords
We Do Not recommend the use of extension cords with this
device. If it is necessary to use one, however, then you must
use only extension cords that are approved for outside use.
These extension cords are identified by a marking
"ACCEPTABLE FOR USEWITH OUTDOOR APPLIANCES".
Extension cords are not recommended unless they are
plugged into a ground-fault-protected receptacle. DO NOT
use damaged extension cords. Also observe the following
specifications:
Cable Length:
Wire Gauge:
Up to 25 feet (8m)
14 AWG
50 feet (15m)
12 AWG
Always disconnect the extension cord from the receptacle
before disconnecting the GFCIfrom the extension cord.
WARNING
"_f
Risk of electrocution.
• Keep all electrical connections dry and off the ground.
• NEVERtouch plug with wet hands.
• NEVERcut or remove grounding blade (round longer pin) on
GFCIattachment plug.