ge.com
Temperature Limiting
Temperature
limiting
can reduce
energy'
costs
by limiting
the
lowest
temperature
that
can be
set fl)r cooling
and
the
highest
temI)erature
that
can be set fin" heating,
Temperature
limiting
is
controlled
by the second
six au_liarv
switches,
The
fit_t three
switches
are
used
to select
tile
cooling
limits,
and
the
remaining
three
switches
are
used
to control
the
heating
limits,
This
teatm'e
is not
available
with
the
Remote
Them_ostat--Class
2.
iBBBBBBBBi BBBBBBB
TL1/C)(Temp.Limit 1 Cool) " _'-
TL2(C)(Temp. L imit 2 Cool)
TL3(C)(Temp. L imit 3 Cool)
°°% iBBBBBBBBi I BBB
TL1(H)(Temp.Limit 1 Heat)
TL2(H)(Temp.Limit 2 Heat)
TL3(H}(Temp.Limit 3 Heat)
Temperature limiting during COOLmode
(all temperatures shown in °F)
UP
DOWN
Minimum
Maximum
NONE
1, 2,3
60°
85°
1
2, 3
64°
85°
1, 2
3
66°
85°
2
1, 3
68°
85°
2, 3
1
70°
85°
1, 2, 3
NONE
72°
85°
1, 3
2
74°
85°
3
1, 2
76°
85°
Temperature limiting during HEATmode
(all temperatures shown in °F)
UP
DOWN
Minimum
Maximum
NONE
4, 5,6
60°
85°
4
5, 6
60°
80°
4, 5
6
60°
78°
5
4, 6
60°
76°
5, 6
4
60°
74°
4, 5, 6
NONE
60°
72°
4, 6
5
60°
70°
6
4, 5
60°
65°
Heat Sentinel
_,_]/eil this switch is enabled
(UP), it turns ON
the heat sentinel
protection
teatm'e.
_,_]th the
switch disabled
(DOWN), the heat sentinel
is
de-actiw_ted.
This teatm'e
automatically
provides
cooling
without
user intedhce.
This helps to
prevent
an excessively
hot room by turning
the
air conditioner
ON at 85°F and OFF at 80°E
oo%qaBBBBaBB]
laaaaaaa,
ale,,.
Heat Sentinel J
Heat Boost (AZ3800only)
_&]/en
this switch
is enabled
(UP) and
outdoor
teml)eratures
are
between
20°F and 46°E
heat
pmnp only operation is locked out. This setting is
used
to provide
SUl)plementa_
T heat
to tile heat
pmnp
operation
in conditions
where
tile heat
pmnp
only
operation
is not
sufficient
to maintain
a consistent,
coi//ti)rtable
i'OOlil tei//l)ei'at/li'e.
NOTE." T hisisan auxilbryswitchforAZ2800 models and
mustremabb the(DOWN)position.
BOOST(Heat Boost Operation) J
Need help?
Do you have a question about the AZ38H12DABM2 and is the answer not in the manual?
Questions and answers