CHANGE OIL FILTER
=
Squeeze (don't twist) pre-cleaner in a clean, dry cloth.
o
Saturate pre-cleaner in engine oil Squeeze in a clean
absorbent cloth to remove excess oil.
Change engine oil filter every 100 hours of operation (every
second oil change).
Before
installing new filter, lightly
lubricate filter gasket with fresh, clean engine oil. Screw
new filter on by hand until gasket contacts the filter adapter
(Fig 16) Then tighten about 3/4 turn further
Start and run
engine for about 30 seconds, then shut down. Recheck oil
level and add oil as necessary.
Finally, start engine and
check for leaks,
NOTE: If you are going to clean the PAPER CARTRIDGE,
do not install the foam pre-cleaner and proceed to instruc-
tions for serving the paper cartridge.
o
Carefully install the foam pre-cleaner
around the car-
tridge.
To service the PAPER CARTRIDGE,
proceed as follows:
o
Clean cartridge by tapping gently on a flat surface.
If
cartridge
is very dirty, replace or wash in a low or
non-sudsing
detergent
and warm
water
solution
Rinse thoroughly
with flowing water from mesh side
until water runs clear.
Let cartridge
dry thoroughly
before using
CAU'RONh DO NOT use petroleum solvents such
as kerosene to clean the element. Such solvents
will cause deterioration of the elemenL DO NOT oll
the elemenL DO NOT use pressure air to clean or
dry the element.
,,
Reinstall paper cartridge, retain with cartridge retainer
and knob. Carefully install foam pre-cleaner
o
Install cover assembly onto air cleaner body
,,
Tighten latch securely
FIG°16
SERVICE ENGINE AIR CLEANER
Your engine will not run properly and may be damaged if
you run it using a dirty air cleaner
Clean or replace foam
pre-cleaner every 25 hours of operation
Service cartridge
every 100 operating
hours or once annually, whichever
comes first Clean or replace more often if operating under
dusty or dirty conditions
To service the foam pre-cleaner
(Fig 17), proceed as follows:
-
The cover is attached to the air cleaner housing by two
latches.
Lift up on the latches to unlock them, then
remove the cover
,,
Carefully remove foam pre-cleaner
from around the
cartridge
,,
Replace
_re-cleaner or wash in liquid detergent and
water.
HOUSING
FIG. 17
CLEAN SPARK ARRESTER
MUFFLER
The engine exhaust muffler has a spark arrester screen.
The screen should be inspected every 100 operating hours
or once each year, whichever comes first
DANGER; LET MUFFLER COOL BEFORE WORK-
_
ING ON IT, CONTACT WITH A HOT MUFFLER OR
ENGINE CAN CAUSE SEVERE BURNS.
NOTE
If you use your generator
on any forest.covered,
brush covered or grass-covered
unimproved
land, it must
have a spark arrester
The spark arrestor must be cleaned
and maintained in good condition by the owner or operator
The preceding is required by law in the State of California.
Other states may have similar laws
Federal laws apply on
federal lands_
Clean and inspect the spark arrestor as follows (Fig. 1B):
o
Remove four screws that retain the screen to muffler_
MUFFLER
SPARK ARRESTER
SCREEN
SCREW"
FIG. 18