Test running
Perform test operation after completing gas leak check at the flare nut
connections
and electrical safety check,
1. Connect the power, press the ON/OFF button on the remote controller to
turn the unit on.
2. Use the MODE button to select COOL, HEAT, AUTO and FAN to check if all
the functions works well.
3. When the ambient temperature is too low(lower than 17°C), the unit cannot
be controlled by the remote controller to run at cooling mode, manual
operation can be taken. Manual operation is used only when the remote
controller is disable or maintenance necessary'.
_,_
[ Auto/CooiO
-
Manual control button
Manual co
u.oo
Auto o I
Cool ® I
®