This unit hasmanyexcitingfeatureswhich
are differentfromthosefoundonstandardPTAC
models.Theownermustbefamiliarwith these
featuresin orderto fully understandthe operationand
capabilityof the unit.
• Intelligence
-- Your unit
has an on board
computer
that
utilizes
real time diagnostics
to prolong
the life of your
unit.
There
is an LED indicator
on the
control
board,
behind
the front
panel,
that
will flash
an error
code
if the unit has detected
some
kind of
faulty
condition.
In many
cases,
the unit will
automatically
clear
the fault
condition
and continue
operating
with
no interruption.
In some
cases,
the
Fig. 2
condition
cannot be cleared and the unit will require service. In those cases, an"Fx'failure
mode will be
displayed
on the digital
display. For a detailed
list of all error codes and"Fx"
conditions,
see Table 5 (page12) -
Status LED Indicator
Definitions
for further
details.
• Memory
-- Your unit also has memory. If power is lost, all of the control
settings
(setpoint,
mode, fan speed, on/off
and configuration)
are remembered.
So when power is restored,
the unit will
start back up in the mode (and configuration)
it was in, when power was lost.
°Quiet
Design--
Not only does the unit have 2 fan motors and a tangential
blower wheel for
optimum
sound, the indoor fan will always run a minimum
of 10 seconds before the compressor,
to
help reduce the sound of the compressor
starting.
• Random
Compressor
Restart--
To help prevent
power surges after a power outage (many PTACs
starting
at the same time),
the compressor
is equipped
with a 2 minute 45 second to 3 minute 15
second
random
restart
delay feature.
Whenever
the unit is plugged in, or power has been restarted,
a random
compressor
restart
will occur to help avoid
power surges.
• Compressor
Protection
-- To prevent short cycling of the compressor
and maximize
it's life, there is a
random start--up
delay of 3 minutes on the compressor
and a minimum
compressor
run time of 3 minutes.
• Automatic
Room Freeze
Protection
-- This protection feature will automatically
ensure the indoor
temperature
does not fall below freezing.
When your PTAC is configured
for freeze protection
(which
is
the default
condition),
then whenever
power is supplied
to the unit, if the unit senses
temperature
below 40°I:, the fan motor and electric
heater are turned
on and will warm the room to 50°F.
Freeze protection
can be switched
off (please
see page 9), change the configuration
switch to turn the
feature
off (see section
on unit configuration).
• Automatic
Quick Warm--Up
(for heat pump models
only)
-- If the room temperature
falls to 5°F
below the set point temperature,
the reverse cycle heat is shut off and the electric
strip heat is turned
on
for one cycle, until room temperature
rises.
. Dual-8
Display
and LED Display
-- Two 8-segment
nixie tubes,
13 LED indicators
(They are HIGH,
MED, LOW, AUTO, COOL, FAN, HEAT, ON/OFF, SETOPINT, INDOOR, STATUS and TIMER)
1. Mode indicator
display:
When the air conditioner
operates
in a certain
mode, the
corresponding
mode indicator
will be lit;
2. The ON/OFF indicator
is in green when the controller
is ON and in red when controller
is OFF.
3. Fan speed display:
When air conditioner
operates
at high, medium,
low or auto fan speed, the
corresponding
indicator
will be lit.
4. Dual-8 display:
Ambient
temperature
can also be displayed
in cooling and heating
modes through
setting
the keypad.
Under cooling
or heating
mode, the dual-8 will display the set temperature
(the dual-8 will display indoor ambient
temperature
under fan mode).
5. If the display data has three bits, the dual-8 will display "ten's digit"+
"unit's
digit" at first and
then display "BLANK"+
"hundred's
digit".
- Fan Configure
for Optimization
of Selected
Application
-- The unit can be optimized
to selected
application
by configuring
the fan to run in continuous
mode or cycle on and off with the compressor
and
electric
heater (can be different
for both heating
and cooling
modes). In cycle mode, the fan will continue
to
run after the compressor
or electric
heater stops in order to blow off any residual
heat or cool left on coil.