Frigidaire FRA106HT10 Use & Care Manual page 12

Packaged terminal air conditioner
Table of Contents

Advertisement

TERMINAL
CONNECTIONS
The wall thermostat
terminal
block is located behind the front panel and is easily accessible
on
control
panel.
,\
\
\\
\\
\\
STATUS LED
J
Wall Thermostat
Energy Management
Terminal
Connections
Terminal
Connections
Fig.20-
Terminal
Connector
and Status
LED Location
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage
or improper operation,
front of
©
©
©
©
©
TYPICAL
WALL
THERMOSTAT
©
©
©
©
NOTES:
TERMINAL BLOCK
1. Use terminal
"O" for heat pump connection
only.
2. Terminal
"C"
(common)
is typically
only
required
for digital
thermostats.
Energy
--
management
(24VAC
in)
--Common
R
W
Y
O See Note 1
GH
GL
C See Note 2
TERMZNAL
DESZGNATION
R
24 VAC
W
Electric Heat
Y
Compressor
O
Reversing Valve
GH
High Fan
GL
Low Fan
C
Common
NOTE: Any incorrect input combinations
will be captured
as
Improper wiring may damage unit electronics. Common
thermostat
wiring
failures
and will light the STATUS LED
busing is not permitted. Damage or erratic operation may
indicator on
main
board (see Intelligent
Self-
Checking
result.
Control
section)
fig,21-Wiring
Connections
ENERGY
MANAGEMENT
INPUT
(FRONT
DESK CONTROL)
The controller
can handle a switch signal from remote energy management
input, called EM signal or front
desk control.
Input must be 24VAC. If system
receives a 24VAC signal, it will turn unit off; otherwise,
the
unit runs in normal control.
This function
will be disabled
under Freeze Guard protection.
See Fig. 20 and
Fig. 21 for terminal
connections.
INTELLIGENT
SELF=CHECKING
CONTROL
Your Frigidaire PTAC has a computer
on-board
that continuously
checks key components
of the unit to ensure
they are operating
properly.
Under normal operation,
unit status indicator
(STATUS, on main PCB), light is
steadily
ON. If there is a major problem,
the unit will shut down and display a diagnostic
failure
code on
the unit's display.
If it is a minor error and the unit can correct
it by itself, the diagnostic
code
will be flashed on the status LED that can easily be seen when the front panel is removed
(see Fig.23).
Failure STATUS codes are defined
in the table below
1
Indoor air temp sensor open/short
2
Indoor coil sensor open or short
3
Outdoor coil sensor open/short
NOTE" When status
4
Freeze Guard protection
ight is flashing, it will
5
Indoor coil freeze protection
3e
ON for 1 seconds
6
Outdoor coil high temp protection
and OFF for another
7
Defrost (heat pump type)
8
Indoor coil high temp protection
1 seconds.
9
Thermostat wiring error
Table 5--STATUS LED Indicator
Definitions
8-segment
display
'FI',
with STATUS light flash
1 times
and off 3 sec, repeat
8-segment display 'F2', with STATUS light flash 2 times and off 3 sec, repeat
8-segment display 'F4', with STATUS light flash 3 times and off 3 sec, repeat
8-segment display 'FP'
STATUS light flash 5 times and off 3 sec, repeat
STATUS light flash 6 times and off 3 sec, repeat
STATUS light flash 7 times and off 3 sec, repeat
STATUS light flash 8 times and off 3 sec, repeat
STATUS light flash 9 times and off 3 sec, repeat
12
© 2010 Electrolux Home Products,[nc.
All rights reserved.