OPERATING
HEATER
AND LIGHTING
INSTRUCTIONS
Continued
7. Depress
and hold down the thermostat
control
knob,
While holding the control
knob down, push the piezo ignitor button
repeatedly to light the pilot. Continue to hold the control knob in for
about 30 seconds after the pilot is lit. Release knob and it will pop
back up. Pilot should remain lit. If it goes out, repeat steps 3 through
7.
• If knob doe_; not pop
up when
released,
stop and immediately
call
your
service
technician
or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control
knob to the "OFF" position and call your service technician or gas
supplier.
8. Attentionl
Gas control has an INTERLOCK
device. When the pilot is
initially !it and the safety magnet is energized (pilot stays "ON") the
INTERLOCK
device becomes operative. If the gas control is turned to
the "OFF"
position or gas flow to the appliance is shut off, the pilot
cannot
be
relighted
until
the
safety
magnet
is
de-energized
(approximately
60 seconds). There will be an audible "click"
when the
safety magnet in the gas control is de-energized.
Pilot can now be
elighted.
Repeat steps 3 through 7.
9. Turn gas control Knob counterclockwise
( _
) to the desired heating
level from "LO" to "HI".
ELECTROOE
P_LOT
_._BURNER
LTHERMOCOUPLE
THERMOSTAT
OPERATION
When the hydraulic thermostat
bulb "senses" the need for heat, the unit cycles
"ON" at a full input rate. The unit remains at this full input rate until the
hydraulic thermostat
bulb is "satisfied". When this happens, the burner will shut
off with the pilot flame remaining lit.
Note: The burner modulates between "ON" and the pilot flame. When the
CGR 18PT is "ON" all three ceramic plaques will "glow". There will never be a
time when only one or two ceramic plaques are "glowing".
The "LO"
and "HI" setting I_as temperature
range of approximately
55 -_F to
90 _ F, respectively.
This is the temperature
at the hydraulic thermostat
bulb, not
the room temperature.
The owner is advised to determine
the particular heat
setting that is desired for comfort, a.s heating requirements
are different for every
owner.
Attention:
If no heat is desired, turn the gas control knob to the "Pilot" position
(not to the "LO" position).
im