Desa Comfort Glow CGP10TLA Owner's Operation And Installation Manual

Vent-free propane/lp gas heater
Hide thumbs Also See for Comfort Glow CGP10TLA:

Advertisement

Quick Links

VENT-FREE
PROPANE/LP
GAS HEATER
OWNER'S
OPERATION
AND INSTALLATION
MANUAL
CGPIOTA
and
CGPIOTLA
IIIIIIIIIIIIIIIIIIIII
WARNING:
If the information
in this manual Is not fol-
lowed exactly,
a fire or explosion
may result causing
property damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone In your building.
• Immediately
call your gas supplier
from
a
neighbor's phone. Follow the gas supplier's in-
structions.
• If you cannot reach your gas supplier, call the fire
department.
--
Installation and service must be performed by a quail-
fled Installer, service agency, or the gas supplier.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause Injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional Information
consult a qualified Installer, ser-
vice agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to Air for
Combustion and Ventilation sec-
tion on page 4 in this manual.
Thls appliance
may be Installed In en aftermarket*
manufactured
(mobile)
home, where not prohibited
by state or local codes,
*Aftermerkot: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product Is
permitted after the mnufaotured (mob,e) home Is sited)
This appliance
Is only for use with the type of gas Indlceted
on the rating plate.
This appliance
Is not convertible
for use with other gases.
Save this manual for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Comfort Glow CGP10TLA and is the answer not in the manual?

Questions and answers

Summary of Contents for Desa Comfort Glow CGP10TLA

  • Page 1 VENT-FREE PROPANE/LP GAS HEATER OWNER'S OPERATION AND INSTALLATION MANUAL CGPIOTA CGPIOTLA IIIIIIIIIIIIIIIIIIIII WARNING: Improper installation, WARNING: If the information in this manual Is not fol- adjustment, alteration, service, or lowed exactly, a fire or explosion may result causing maintenance can cause Injury or property damage, personal injury, or loss of life.
  • Page 2: Safety Information

    CPOlOT, an. C OP IOT-, VENT-FREE PROPANE/LP HEATER SAFETY 14. Do not use heater if any part has been If you smell gas under water. Immediately call a quali- • shut off gas supply INFORMATION fied service technician to inspect the •...
  • Page 3: Local Codes

    OWNER'S MANUAL PRODUCT PRODUCT IDENTIFICATION FEATURES Safety Device ignitor Button Control Knob This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is arequired feature for vent- free room heaters. The ODS/pilot shuts off IIIllllllllllllllllll the heater if there is not enough fresh air.
  • Page 4 Confined and Unconfined PROVIDING ADEQUATE AIR FOR Spaces VENTILATION COMBUSTION The National Fuel Gas Code (ANSI Z223.1, The following is excerpts from National VENTILATION 1992 Section 5.3) defines a confined space Fuel Gas Code. NFPA 54/ANSl Z223.1, as a space whose volume is less than 50 Section 5.3, Air for Combustion and Venti- cubic feet per 1000 Btu per hour (4.8 cubic lation.
  • Page 5: Determining Fresh-Air Flow For Heater Location

    OWNER'S MANUAL AIR FOR COMBUSTION VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 6: Gas Heater

    VENT-FREE PROPANE/LP HEATER AIR FOR COMBUSTION VENTILATION 12" Continued VENTILATION AIR Ventilation Grills Ventilation Air From Inside IntoAdjoiningRoom, Ventilation Option2 Building Grills Remove into Adjoining This fresh air would come from anadjoining Room, Door into unconfined space. When ventilating Option 1 Adjoining adjoining unconfined space, you must pro- Room,...
  • Page 7: Installation

    OWNER'S MANUAL INSTALLATION LOCATING HEATER CEILING This heater is designed to be mounted on a wall. • S6" NOTICE: This heater Is intended for use as supplemental heal Use 6" Minimum WARNING: Maintain the mini- Minimum this heater along with your pri- From mum clearances shown In Figure mary heating system.
  • Page 8 VENT-FREE PROPANE/LP HEATER INSTALLATION Installing Bottom Mounting Screw Wall Continued (thick wall Locate bottom mounting hole. This shown) Installing Two Mounting Screws hole is near bottom on back panel of 1/16" heater (see Figure I1). Note: Wall anchors and mounting screws Mark screw location on wall.
  • Page 9: Connecting To Gas Supply

    OWNER'S MANUAL Installation must include a manual shutoff INSTALLATION Install sediment trap in supply line as shown valve, ground joint union, and plugged in Figure 13. Locate sediment trap where it Continued 1/8" NPT tap. Locate NPT tap within reach is within reach for cleaning.
  • Page 10 INSTALLATION Test Pressures Equal To or Less Than Pressure Testing Heater Gas 1/2 PSIG Connections Continued Close manual shutoff valve (see Fig- Open manual shutoff valve (see Fig- CHECKING ore 14). )are 14). CONNECTIONS Pressurize supply piping system by ei- Open propane/LP supply tank valve.
  • Page 11: Operating Heater

    OWNER'S MANUAL OPERATING Turn control knob counterclockwise LIGHTING to desired heating leveL The HEATER INSTRUCTIONS main burner should right. Set control knob to any heat level between HI STOP! Read the safety information, and LO. column 1. READ BEFORE FOR YOUR SAFETY I Make sure manual shutoff valve is LIGHTING CAUTION: Do not try to adjust...
  • Page 12: Inspecting Burner

    VENT-FREE PROPANE/LP HEATER OPERATING BURNER FLAME PATTERN HEATER MANUAL LIGHTING PROCEDURE Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner Continued Remove front panel (see Figure 10, flame pattern. The incorrect burner flame page 8). pattern shows yellow tipping of the flame.
  • Page 13: Specifications

    OWNER'S MANUAL CLEANING SPECIFICATIONS MAINTENANCE CGP10TA/CGP10TLA 5,000110,000 Btu (Variable) Type Gas Propane/LP Only WARNING: Turn off heater Piezo Ignition and let cool before cleaning. 8" W.C. Pressure Regulator Setting Inlet Gas Pressure (inches of water) Maximum 14" CAUTION: You must keep control areas, burner, and circu- II"...
  • Page 14: Troubleshooting

    C,OLO,, an, C aP10,-, VENT-FREE PROPANE/LP HEATER TROUBLESHOOTING AIkWARNING: Turn off heater CAUTION: Never use a wlre, and let cool before servicing. needle, or similar object to clean Note: All troubleshooting items are listed Only a qualified service per- ODS/pllot. This can damage ODS/ in order of operation.
  • Page 15 OWNER'S MANUAL TROUBLESHOOTING Continued POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1. Burner orifice is clogged 1. Clean burner orifice (see Cleaning and Burner does not light after ODS/pilot is lit Maintenance, page 13) or replace burner orifice 2. Burner orifice diameter is too small 2.
  • Page 16 C,alOT, and C QPIOT VENT-FREE PROPANE/LP HEATER TROUBLESHOOTING Continued _IL WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone In your building.
  • Page 17: Replacement Parts

    OWNER'S MANUAL PARTS CENTRAL REPLACEMENT Energy East Coast Products 707 Broadway PARTS These Parts Centrals are privately-owned W. Long Branch, NJ 07764 businesses. They have agreed to support our 908-870-8809 Note: Use only original replacement parts. customer's needs by providing original re- 1-800-755-8809 This will protect your warranty coverage for placement parts and accessories.
  • Page 18: Illustrated Parts Breakdown

    CP lOT, and C OPlOT-, VENT-FREE PROPANE/LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN CGP10TA CGP10TLA ODS/PILOT...
  • Page 19: Parts List

    OWNER'S MANUAL PARTS LIST This list contains replaceable parts used in your heater, When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. CGP10TA CGP10TLA PART NUMBER DESCRIPTION QTY. 098304-01 Screw, #10 x 3/8 _ 099467-02 Front Panel Assembly, Earthtone (CGP10TA)
  • Page 20: Warranty

    WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the tight to amend these specifications at any time without notice. The only warranty applicable is our standard written wa_anty.

This manual is also suitable for:

Comfort glow cgp10ta

Table of Contents