CONNECTING
TO GAS
SUPPLY
NOTICE
A qualified
service
person
must connect
heater to gas supply.
Follow
all local
codes.
CAUTION
Never connect
heater
directly
to the propane/LP
supply.
This
heater
requires
an external
regulator
(not supplied).
Install the
external
regulator
between
the heater
and propane
supply.
Propane/LP
Supply Tank
Extemal
Regulator
The installer must supply an external regulator. The external regulator
will reduce
incoming
gas pressure.
You must i'educe incoming gas pressure to between
11 and
14 inches of water. If you do not reduce incoming gas pressure, heater regulator
damage could occur. Install external regulator
with the vent pointing down as
shown in Figure 7.
Pointing
the vent down protects it from freezing rain or sleet.
Vent-Pointing
Down
Figure 7 - External Regulator With Vent Pointing Down
CAUTION
Use only new, black iron or steel pipe. Internally-tinned
copper
tubing may be used in certain
areas. Check your local codes.
Use
pipe of large enough
diameter
to allow proper gas volume to heater.
If pipe is too small, undue loss of pressure
will occur.
Typical
Pipe Diameters
CGRIgPT:
3/8" or greater
CGR30PT:
I/'2" or greater
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT
tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be
upstream from heater (see Gas Connection,
page 14).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION
Use pipe joint
sealant
that is resistant
to liquid
petroleum
(LP) gas.
Install sediment trap in supply line as shown in Gas Conneclinn, page 14. l.,oc.ate
ediment trap where it is within reach for cle_tning. Locate sediment trap where
trapped matier is not likely to freeze, A sediment trap traps moisture and
contaminantS. This keeps them from going into heater controls. If sediment trap
is not installed or is instal.led wrong, heater may not run propedy.