Desa Comfort Glow CGR30PT Owner's Operation And Installation Manual page 15

Vent-free propane gas heater
Table of Contents

Advertisement

CHECKING
GAS
CONNECTIONS
Contmued
3, Pressurize supply piping system by either using compressed
air or
opening propane/LP
supply tank valve.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap
and water to gas joints, Bubbles forming show a leak.
5. Correct all leaks at once.
Test Pressures Equal To or Less Than 1/2 PSIG
l.
Close manual shutoff valve (see Figure 8).
2. Pressurize supply piping system by either using compressed
air or opening
propane/LP
supply tank valve.
3. Check all joints from propane supply tank to manual shutoff valve (see
Figure 9). Apply mixture of liquid soap and water to gas joints. Bubbles
forming show a leak.
4. Correct all leaks at once.
PRESSURE
TESTING
HEATER
GAS CONNECTIONS
1. Open manual shutoffvalve
(see Figure 8).
2. "Open propane supply tank valve.
3. Make sum control knob of heater is in the OFF position.
4. Cl_ck
all Dints from manual
shutoff
valve to control valve (see Figure 9).
Apply mixture of liquid soap and water to gas joints. Bubbles fomaing show
a leak.
5. Correct all leaks at once.
6. Light healer (see Operating
Heater, page
16). Checkthe
restofthe
internal
joints for leaks.
7. Turn off healer (see To Turn OffGas
to Appliance,
page _a)
Manual
___
Open
Shutoff
Valve
z-
-?
Closed
Figure 8 - Manual Shutoff Valve
Propane/LP
Supply Tank
Control Valve Location
IIIIIIIIIIIIIIIIIIIIIIIIIII
_
IIIIII
o.
o •
__
4
_{-_i
._o
i
II
_Manual
Shutoff
Valve
Figure
9
- Checking
Gas Joints