Champion MasterCool ADA35 Owner's Manual

Champion MasterCool ADA35 Owner's Manual

Essick air products, inc. evaporative cooler owner's manual

Advertisement

Read Carefully All Of This Manual
Before Installing The Unit
Lea Con Cuidado Todo Este Manual Antes De
Instalar La Unidad
Circle the model of your cooler and
record the serial number below.
Encierrre con un circulo el modelo de su
enfriador y escribe el número de série abajo.
Serial #
Número De Série
Safety Instructions .......................................................................... 1
Operation ......................................................................................1-2
Installation Instructions ................................................................2-3
Electrical Wiring Diagram .............................................................. 3
Maintenance Section ....................................................................3-4
Warranty .......................................................................................... 5
Vea el Español en el interior.
Read And Save These Instructions
Safety Rules
1. Read instructions carefully.
2. Electrical hook up should be done by a qualifi ed electrician, so that
all electrical wiring will conform to your local standards.
3. Always turn OFF POWER and UNPLUG motor and pump inside
the cooler before installing or performing any maintenance.
4. Your cooler will run on either 120V or 240V A.C., single phase,
60 Hz (cycle) current.
5. Motor and pump have a grounded, molded plug and an automatic
thermal overload switch which will shut motor off when it overheats.
The motor will restart automatically when it cools down.
WARNING:
To reduce the risk of fi re or electric shock, do not
use this fan with any "solid-state fan speed control device."
Evaporative Cooling
Evaporative cooling is nature's way of cooling. When air is moved over
a wet surface, water is evaporated and heat is absorbed. When stepping
out of swimming pool with the wind blowing, evaporative cooling makes
you feel cool, even though the air may be warm.
110498-2

Table Of Contents

Parts List (ADA35, ASA35) .......................................................6-7
Parts List (51 & 71 Series Down Discharge) ...............................8-9
Parts List (51 & 71 Series Side Discharge).............................. 10-11
Parts List (51 & 71 Series Up Discharge) ................................12-13
Instrucciones en Español .........................................................13-16
This unit works on the same principle. Air is drawn across wet fi lter pads
where the air is cooled by evaporation and then circulated throughout
the building. It is this combination of cooled air and the movement of
air over the skin which makes it feel cool.
Unlike refrigeration systems which recirculate the air, an evaporative
cooler continually brings in fresh air while exhausting old air. You are
completely replacing the air every 2 to 4 minutes by opening windows or
doors or a combination of both. The air is always fresh, not stale, laden
with smoke and odors as happens with refrigerated air conditioning.
To eliminate the delivery of hot air when starting the cooler, start the
pump only for the fi rst few minutes, then turn on the blower motor.
These coolers may be used without water for ventilation purposes. When
outside air is cool (for example, at night) or when humidity is high the
water pump can be turned off.
A cooler can also be installed with a thermostat and attic exhaust dampers
to provide completely automatic operation.
www.championcooler.com
Models
ADA35
ASA35
ADA51
ADA5112
ASA51
ASA5112
AUA51
AUA5112
ADA71
ADA7112
ASA71
ASA7112
AUA71
AUA7112

Operation

12-09

Advertisement

Table of Contents
loading

Summary of Contents for Champion MasterCool ADA35

  • Page 1: Table Of Contents

    AUA71 Table Of Contents Specifi cation Tables (Tablas de Especifi caciones) ... 5 Parts List (ADA35, ASA35) ...6-7 Parts List (51 & 71 Series Down Discharge) ...8-9 Parts List (51 & 71 Series Side Discharge)... 10-11 Parts List (51 & 71 Series Up Discharge) ...12-13 Instrucciones en Español ...13-16...
  • Page 2: Installation Instructions

    NOTE: You can separate the wet module from the blower module by removing the 4 bolts (2 bolts in ADA35 and ASA35) from the wet module side (Fig. 1) Motor Installation • Install motor cord. For typical 120V installation, connect motor cord to motor using the following color code: Black - Hi, Red - Low, White - Com., Green - Ground.
  • Page 3: Electrical Wiring Diagram

    • Adjust pulley if necessary. If amperage draw is less than motor rat- ing, turn off electrical power and remove inspection panels (top pan for models ADA35 and ASA35). Unplug motor inside cooler, this 120 Volts Blue/Black...
  • Page 4: Troubleshooting Guide

    • Check belt tension. A 3 lb. force should defl ect the belt 3/4 inches (see Fig. 11). Readjust belt if needed. • Oil bearings. The blower bearings and cooler motor in this unit should be oiled with a few drops of non-detergent 20/30 weight oil once each year.
  • Page 5: Limited Warranty

    Anchura 13 5/8 17 3/4 17 3/4 19 3/4 19 3/4 Model Drive Belt Part # Modelo Correa - N° ADA35 110209 (4L-430) ASA35 110207 (4L-460) ADA51 & 110208 (4L-520) ADA5112 110229 (4L-530) - 3/4 HP ASA51 & 110212 (4L-570) ASA5112 AUA51 &...
  • Page 6: Parts List (Ada35, Asa35)

    * See the motor specifi cation table on page 5. / Vea la tabla de especifi caciones del motor en la página 5. NOTE: Standard hardware items may be purchased from your local hardware store. NOTA: Artículos de uso corriente pueden comprarse en la ferretería de su localidad. ADA35 ASA35 222130-028...
  • Page 7 Parts Drawing / Dibujo De Piezas ADA35, ASA35 110498-2...
  • Page 8: Parts List (51 & 71 Series Down Discharge)

    Replacement Parts List / Lista De Piezas De Repuesto When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. / Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora. Cooler model number / El modelo de su enfriador Cooler serial number / Número de serie de la unidad Motor HP / C.V.
  • Page 9 Parts Drawing / Dibujo De Piezas ADA51 / ADA5112 ADA71 / ADA7112 110498-2...
  • Page 10: Parts List (51 & 71 Series Side Discharge)

    Replacement Parts List / Lista De Piezas De Repuesto When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. / Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora. Cooler model number / El modelo de su enfriador Cooler serial number / Número de serie de la unidad Motor HP / C.V.
  • Page 11 Parts Drawing / Dibujo De Piezas ASA51 / ASA5112 ASA71 / ASA7112 110498-2...
  • Page 12: Parts List (51 & 71 Series Up Discharge)

    Replacement Parts List / Lista De Piezas De Repuesto When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. / Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora. Cooler model number / El modelo de su enfriador Cooler serial number / Número de serie de la unidad Motor HP / C.V.
  • Page 13: Instrucciones En Español

    Lea Y Conserve Estas Instrucciones Reglas De Seguridad 1. Lea las instrucciones con cuidado. 2. Las conexiones eléctricas deben ser hechas por un electricista com- petente, para que todo el cableado eléctrico cumpla con los requisitos establecidos en su localidad. 3.
  • Page 14 NOTA: Para separar la sección de agua de la sección de la rueda, remueve los cuatro pestillos (los modelos ADA35 y ASA35 tiene 2) del lado de la sección de agua (fi g. 1). Instalación Del Motor •...
  • Page 15 (la tapa para modelos ADA35 y ASA35). Desconecte el motor dentro de la caja para protegerse en caso de que alguien intente poner en marcha el aparato mientras usted está...
  • Page 16 Preparar La Unidad Para El Invierno • Drene el agua. Drene siempre toda el agua de la unidad y del tubo de abas- tecimiento de agua cuando no use el enfriador durante períodos prolongados, especialmente al fi n de la temporada. El tubo debe quedarse desconectado del enfriador y del abastecimiento de agua para que no lo congele.

Table of Contents