Vea el español en el interior.
Evaporative Cooling
With this unit being a fresh air system, you are not trapped with
recirculating air that can become stale, laden with smoke and odors,
as happens with refrigerated air conditioning systems. Instead,
you are completely replacing the air every 2 to 4 minutes by either
opening doors or windows or a combination of both to exhaust the
air continually.
How much should you open your windows? To obtain the maximum
cooling capacity of your cooler, you should open your windows until
the air inside the house is nearly balanced with the air outside. As
you open your windows you decrease the pressure buildup inside the
home, and the cooler is able to output increasingly more air until the
capacity of the cooler is reached.
One method to determine when the air is reasonably balanced is to
place a piece of tissue paper up against the screen of the window
furthest from the cooler and adjust the opening of the windows in the
house until the tissue paper stays lightly on the screen. If the tissue
plasters itself to the screen, open the windows more. If it falls, close
the windows more.
110499
C H A M P I O N • E S S I C K
Window Evaporative Cooler
Manual
www.championcooler.com

Safety Rules

1. Read instructions carefully.
2. Electrical hook up should be done by a qualifi ed electrician, so
that all electrical wiring will conform to your local standards.
3. Unit must be in the OFF POSITION and UNPLUGGED from
power receptacle when installing or performing any mainte-
nance.
4. Your cooler will run on 120 volt AC., 60 Hz (cycle) current
only.
5. Motor and pump are grounded and have an automatic thermal
overload switch which will shut motor off when it overheats. The
motor will restart automatically when it cools down.
WARNING
: To reduce the risk of fi re or electric shock, do not
use this fan with any "solid-state fan speed control device."
Operation
To eliminate delivery of hot air when starting cooler, turn on pump
only for the fi rst few minutes, then turn on the blower motor.
These coolers may be used without water for ventilation purposes.
When outside air is cool (for example, at night) or when humidity is
high the water pump can be turned off.
8-08

Advertisement

Table of Contents
loading

Summary of Contents for Champion Essick N28W

  • Page 1: Safety Rules

    Models WCM28 N28W Serial # Número De Serie Read Carefully All Of This Manual Before Installing The Unit Lea Con Cuidado Todo Este Manual Antes De Instalar La Unidad Read And Save These Instructions Vea el español en el interior.
  • Page 2: Installing House Legs

    Cooler Installation Installing House Legs • NOTE: If installing unit without the use of the installation kit, omit these directions and those pertaining to Fig. 2. • Remove two corner screws in bottom pan (A-Fig. 1). • Place house leg bracket at corner of bottom pan, using two top holes in bracket (B-Fig.
  • Page 3: Winter Shut Down

    • Clean pump. Cleaning the pump is necessary once a year at start-up. For your safety, turn unit off and unplug from power receptacle. Remove the pump from the mount slot. Remove the base of the pump (Fig. 7). Clean the pump and turn the impeller to ensure free operation.
  • Page 4: Parts List

    NOTA: Artículos de uso corriente pueden comprarse en la ferretería de su localidad. General Specifi cations / Especifi caciones Generales Weight (lbs.) Peso (libras) Model No. Modelo Operating Seco WCM28, N28W Electrical Specifi cations / Especifi caciones Eléctricas Model No. Volts Modelo Voltios WCM28, N28W Cabinet Dimensions (in.)
  • Page 5: Limited Warranty

    Register your product online at www.championcooler.com/eac/onlineregistration-eac.htm This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover damages incurred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us any other or different liability in connection with this product. Terms And Conditions Of The Warranty For Eight Years from date of purchase, we will replace the original base assembly if water leakage should occur due to rust out.
  • Page 6: Reglas De Seguridad

    Lea Y Conserve Estas Instrucciones Reglas De Seguridad 1. Lea las instrucciones con cuidado. 2. Las conexiones eléctricas deben ser hechas por un electricista competente, para que todo el cableado eléctrico cumpla con los requisitos establecidos en su localidad. 3. La unidad debe estar APAGADA y DESCONECTADA de la electricidad cuando se instale o haga cualquier mantenimiento.
  • Page 7: Mantenimiento

    • Coloque la ventana detrás de la guarda de retención. Levante la parte trasera del enfriador para que la ventana (D-fi g. 2) pueda bajarse y quedar detrás de la parte superior de la guarda de retención (C-fi g. 2). •...
  • Page 8: Garantía Limitada

    Problema Causa Posible No arranca o 1. No llega corriente no sale aire • Fusible fundido • Cortacircuito desacti- vado • Cable eléctrico daña- 2. Motor recalentado • Cojinetes están secos 3. Motor parado Sale poco 1. Insufi ciente abertura aire cuando para que salga el aire la unidad...