Variable
Provides:
OperStatus
The operational status of the module:
online(1) the module is functioning properly;
offline(2) the module is not available;
testing(3) the module is under testing; and
faulty(4) the module is defective in some way.
LastChange
This object contains the value of sysUpTime when the module entered its
current operational status. A value of zero indicates that the operational status
of the module has not changed since the agent last restarted.
FPortCapacity
The number of ports that can be contained within the module. Within each
module, the ports are uniquely numbered in the range from 1 to
fcFeModuleFPortCapacity inclusive.
ModuleName
The name identifier of the module.
Variable
Provides:
ModuleIndex
Module index.
FxPortIndex
Port index.
Name
Name identifier of the F_Port. Each F_Port has a unique port name in the
address space of the fabric.
FC-PHVersHigh Highest or most recent version of FC-PH that the F_Port is configured to
support.
FC-PHVersLow Lowest or earliest version of FC-PH that the F Port is configured to support.
BBCredit
Total number of receive buffers available for holding a class 1 connect-request,
or class 2 or 3 frames from the attached N_Port. It is for buffer-to-buffer flow
control in the direction from the attached N_Port (if applicable) to the F_Port.
RxBufferSize
Largest Data_Field size (in octets) for an FT 1 frame that can be received by the
F_Port.
R_A_TOV
Resource allocation time out value configured for the F_Port. This is used as
the timeout value for determining when to reuse an N_Port resource such as a
Recovery_Qualifier. It represents E_D_TOV (see next variable) plus twice the
maximum time a frame may be delayed within the fabric and still be delivered.