Table 15 Storage System components information
Name
DKURaidListIndexSerialNumber
::=dkuHWEntry(1)
DKUHWPS
::=dkuHWEntry(2)
DKUHWFan
::=dkuHWEntry(3)
DKUHWEnvironment
::=dkuHWEntry(4)
DKUHWDrive
::=dkuHWEntry(5)
NOTE:
The status of each component is indicated as follows:
1: Normal.
2: Acute failure detected.
3: Serious failure detected.
4: Moderate failure detected.
5: Service failure detected.

raidExMibDKCHW2

raidExMibDKCHW2 indicates the status of the storage system components.
34
SNMP Supported MIB
Type
Description
Storage system product
INTEGER
number (index).
INTEGER
Status of power supply.
INTEGER
Status of fan.
Status of environment
INTEGER
monitor.
INTEGER
Status of drive.
MIB Value
Attribute
1-99,999
read-only
Note
read-only
(1 digit)
Note
read-only
(1 digit)
Note
read-only
(1 digit)
Note
read-only
(1 digit)