40" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
2. Remove the 3 loose nuts (after you removed the
rubber band) on the terminal block using 3/8" nut
driver or socket.
3. Connect the neutral white wire of the copper power
supply cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black wires
connected to the left terminal).
4. Replace the 3 nuts on the terminal block (see figure
3).
5. Lower the terminal cover and replace the 3 screws.
Terminal
Block
Black
wire
A
strainrelief
supplied by the
user
must be installed at
this location
Figure 3
Four Conductor Wire Connection to Range
(mobile homes)
1. Remove the 3 screws at the lower end of the rear wire
cover, then raise the lower end of the rear wire cover
(access cover) upward to expose range terminal
connection block (see figure 2).
2. Remove the three loose nuts (after you removed the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper power
supply cord to the frame of the appliance with the
ground screw, using the hole in the frame where the
ground strap was removed (see Figure 4).
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
(Models with Electric Ovens and Gas Cooktop)
Silver colored Terminal
Red wire
White Wire
(Neutral)
Grounding
Strap
1-1/8" Dia.
Direct
Connection
To 240 V
Hole. Punch
receptacle
out knockout
for 1-3/8" Dia.
Cord Kit Hole
6. Replace the 3 nuts on the terminal block (see fig. 4).
7. Lower the terminal cover and replace the 3 screws.
Terminal Block
1-1/8" Dia.
Direct
Black
Wire
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
A user
supplied
strain-relief
must be installed
at this location
NOTE: Be sure to remove the supplied
grounding strap
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit breaker,
fuse box or junction box, use flexible, armored or non
metallic sheathed copper cable (with grounding wire).
Supply a U.L. listed strain-relief at each end of the cable.
At the appliance end, the cable goes through the Direct
Connection Hole (see figure 4) on the Cord Mounting
Plate. Wire sizes (copper wire only) and connections must
conform to the rating of the appliance.
Where local codes permit connecting the appliance
grounding conductor to the neutral (white) wire
(see Figure 5).
(The 3-conductor cord or cable must be replaced with a
4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
4
Silver Colored
Terminal
Red
Wire
Neutral
(White
Wire)
Ground
(Bare Copper
Wire)
To 240 V receptacle
Figure 4