INSTALLATION
AND SERVICE MUST BE PERFORMED BY
A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
If the information
in this manual
is not followed
exactly,
a fire or explosion
may
result causing property
damage,
personal
injury or death.
FOR YOUR SAFETY:
--
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
--
WHATTO
DO IFYOU SMELLGAS:
•
Do nottrytolightanyappliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
•
If you cannot reach your gas supplier, call the fire department.
--
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Do not pinch the power supply cord or the flexible gas conduit
between the range and the wall.
Shave Raised Edge
to Clear
Do not seal the range to the side cabinets.
31 1/2" (81 cm)
**NOTE: 30" (76.2 cm) minimum clearance between the
Wide Cooktop
Rim.
cooktop and the bottom of the cabinet when the bottom of
wood or metal cabinet is protected by not less than _A" (0.64
1 _/2" Max.
cm) flame retardant millboard covered with not lessthan No. 28
(3.8 cm Max.)
MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6
rnm) aluminum, or 0.020" (0.5 mm) copper.
36" (91.4 cm) minimum clearance when the cabinet is
unprotected..
30" Min.
13"
76.2 cm Min.
(33 cm)
18" Min.
(45.7 cm) Min.
• NOTE: Allow at
least 19 /4" (48.9 cm)
clearance for door
Locate Cabinel
Doors 1" (2.5
1 5/16"
cm) Min.
cm)
from Cutout
J
Opening.
• Door Open
(see note)
A. HEIGHT
BIWIDTH
Regulator
* Note: For 29" (73.7
cm) cutout wide
opening, you must call
for optional
side
panels and clear wide
cooktop
rim as shown
in the "Countertop
Preparation"
section
(see page 6).
Grounded
Jonction Box or Wall
Outlet Should Be Located 8" to
17" (20.3 cm to 43.2 cm) From
Right Cabinet and 2" to 4" (5.1
cm to 10.2 cm) From Floor.
c DE,TN
E.M,N,MUM UTOU
" Ni,C"T
TOFRONT CUTOUT I'
......
i
"OF
OF RANGE
WDTH
UL'!H
C©UNTERTOP
FRONT
35 3/8" (90 cm)
30"
28 5/16"
30"
21 3/4" (55,2 cm) Min.
36" (91,4 cm) standard
OF
36 3/8" (92 cm)
(76,2 cm)
(71 ,gem)
(76,2 cm)
22 1/8" (56,2 cm) Max.
35 3/8" (90cm) min.
CABINET
24" Min.
cm Min.)
22 7/8"
*
(58.1 cm) rain.
23 1/4"* -_
(59.05 crn) max.
_--1 1/8"
(2.86 cm)
_G
_
Ref.
* For cutouts below 22 7/8", appliance
G. Minimum
Cutout
Depth
is increased
to 24"
(61 cm) with
backguard,
will slightly show out of the cabinet.
NOTE: Wiring
diagram
for these appliances
are enclosed
in this booklet.
P/N 318201661
(0305)
Rev. A
English - pages 1-11
Espahol - paginas 12-22
Wiring Diagrams - pages 213-24