Location Requirements - KitchenAid KWCU460WS00 Installation & Use Manual

36" (91.4 cm) and 48" (121.9 cm) designer commercial-style wall-mount canopy range hood
Hide thumbs Also See for KWCU460WS00:
Table of Contents

Advertisement

Available languages

Available languages

Parts needed
Home power supply cable
1 - ½" (12.7 mm) UL listed or CSA approved strain relief
2 UL listed wire connectors
1 wall or roof cap
Metal vent system
2 - 250-watt max heat lamp bulbs
Parts supplied
Remove parts from packages. Check that all parts are included.
3 metal grease filters for 36" (91.4 cm) models
4 metal grease filters for 48" (121.9 cm) models
10 - #10 Phillips head mounting screws for 36" (91.4 cm)
models
12 - #10 Phillips head mounting screws for 48" (121.9 cm)
models
4 - washer head screws
4 - flat head screws
4 - "L" brackets
Lower chimney cover
Upper chimney cover
Damper (2 for 48" [121.9 cm] model)

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located inside the range hood on the rear wall of the
range hood.
Canopy range hood location should be away from strong draft
areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
The canopy range hood is factory set for venting through the roof
or through the wall.
All openings in ceiling and wall where canopy range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
4
Product Dimensions
Vented Installations
14 " (37.8 cm)
24 " (63.2 cm)
36" (91.4 cm)
or 48" (121.9 cm)
Installation Dimensions
36" (91.4 cm) or 48" (121.9 cm)
or cabinet opening width
(if installed between cabinets)
18" (45.7 cm) min.
clearance upper
cabinet to countertop
36" (91.4 cm)
countertop height
*NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soffit heights depending on the
distance "X" between the bottom of the range hood and the
cooking surface. For higher ceilings, a 39" (99.1 cm) Chimney
Extension Kit Part Number W10197714 (Stainless Steel), is
available from your dealer or an authorized parts distributor. The
chimney extension replaces the upper chimney shipped with the
range hood.
IMPORTANT:
Minimum distance "X": 30" (76.2 cm)
Suggested maximum distance "X": 36" (91.4 cm)
For vented installations, the chimneys can be adjusted for
ceilings between 8' 4¼" (2.55 m) and 9' 3¼" (2.83 m).
37"
(94.0 cm)
21 "
max.
(54.0 cm)
min.
" (20.0 cm)
25" (63.5 cm)
See Note*
X*

Advertisement

Table of Contents
loading

Table of Contents