Regency Ultimate U39-NG1 Owners & Installation Manual page 16

Direct vent freestanding gas stove
Table of Contents

Advertisement

INSTALLATION
Horizontal Venting with Two (2) 90
One 90
o
elbow = Two 45
o
elbows.
Option
V
A)
3' Min.
2' Max.
B)
5' Min.
3' Max.
C)
8' Min.
4' Max.
With these options, maximum total
pipe length is 30 feet with minimum
of 8 feet total vertical and maximum
4 feet total horizontal.
Please note minimum 1 foot
between 90
o
elbows is required.
Lengths do not include elbow
indicated
Vent restrictor position A (fully
open), Refer to the "Venting Ar-
rangement" section.
Vertical Venting with Two (2) 90
o
One 90
elbow = Two 45
Option V
H
A)
1' Min.
1' Max. 1' Min.
B)
1' Min.
2' Max. 2' Min.
C)
2' Min.
3' Max. 2' Min.
D)
2' Min.
4' Max. 2' Min.
With these options, max. total pipe length is 30
feet with min. of 4 feet total vertical and max. 4 feet
total horizontal.
Please note min. 1 foot between 90
required.
Lengths do not include elbow indicated
Vent restrictor position A (fully open). Refer to
the "Venting Arrangement" section.
16
o
Elbows
H + H1
o
Elbows
o
elbows.
V1
V + V1
2' Min.
3' Min.
4' Min.
4' Min.
o
elbows is
®
Regency
U39 ULTIMATE Direct Vent Freestanding Gas Stove

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultimate u39-lp1Ultimate u39

Table of Contents