INSTALLATION
Framing
Dimensions
A
B
*
C
D
E
F
G
H
I
J
K
L
*
Framing depth measurement is noted with the side nailing strips set as far forward on the fi rebox as possible.
The side nailing strips can be adjusted back up to 1" to allow for varying thicknesses in non-combustible mate-
rial & wall fi nishes.
Important: The minimum framing dimensions given for height, width and depth must be maintained even if
using non combustible materials.
Dangerous operating conditions will occur if minimum framing dimensions are not adhered to.
A
B
14
Description
Framing Height
Framing Width
*
Framing Depth
Minimum Height to Combustibles
Corner Wall Depth
Corner Facing Wall Width
Vent Centerline Height
Non-combustible facing height
Gas Connection Opening Height
Gas Connection Height
Gas Connection Inset
Gas Connection Opening Width
Metal Stud
(Header)
on edge
F
46-5/8" (1184mm)
101-7/8 (2586mm)
7-1/4" (184mm)
D
H
Non-Combustible
Facing
C
E
(Located on the right side of the fireplace)
HZ54E
60" (1524mm)
22" (559mm)
51" (1295mm)
72" (1829mm)
44" (1118mm)
20" (508mm)
1-1/2" (38mm)
4" (102mm)
3-1/4" (83mm)
Metal Stud (Header)
on edge
G
I
J
K L
Regency Horizon HZ54E Gas Fireplace