Kenmore 625.385010 Owner's Manual page 10

Advanced two-stage drinking water fiter
Hide thumbs Also See for 625.385010:

Advertisement

Available languages

Available languages

Supply
water
pressure
limits
.........................................
30-125 psi (207-862
kPa)
Supply
water
temperature
limits
...........................................
40-100
°F (5-40 °C)
Inlet - Outlet
.....................................................
3/8" O.D. tubing,
included
This system conforms
to NSF/ANSI
42 and 53 for the specific performance
claims as verified and substantiated
by test data.
Installations
In The Commonwealth
Of Massachusetts:
The Commonwealth
of Massachusetts
requires
instal-
lation be performed
by a licensed
plumber.
Plumbing
code 248--CMR of the Commonwealth
of Massachusetts
must be followed
in these cases.
Cause:
Tubing not pushed in all the way.
Correction:
Push Tubing all the way into fittings.
See Page 8.
Cause:
Tubing not cut square.
Correction:
Cut tubing square. See Page 8.
Remove tube from connection. Remove nicked portion
Cause:
Tubing nicked.
Correction:
by cutting tube to shorter length. Reinsert in connection
See Page 8.
Remove tube from connection. Remove problem area
Cause:
Outer tubing surface not smooth.
Correction:
by cutting tube to shorter length. Reinsert in connection
See Page 8.