Download Print this page

Craftsman 919.167221 Owner's Manual page 19

Permanently lubricated single stage portable air compressor

Advertisement

To Replace
Regulator
1.
Release all air pressure from air
tank, See "To Drain Tank" in the
Maintenance section.
2.
Unplug compressor.
3.
Remove the outlet pressure
gauge and quick connect (if
equipped) from the regulator.
4.
Remove the regulato_
5.
Apply pipe sealant tape to the
nipple,
6.
Assemble the regulator and
orient as shown,
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
Regulator
7.
8.
Reapply pipe sealant to outlet
pressure gauge and quick
connect,
Reassemble outlet pressure
gauge and quick connect, Odent
outlet pressure gauge to read
correctly. Tighten quick connect
with wrench,
19- ENG
D27304

Advertisement