Permanently lubricated tank mounted air compressor
Hide thumbs Also See for 919.167242:

Advertisement

Available languages

Available languages

Quick Links

Owner's Manual
I CRRFTSMRN1
Permanently
Lubricated
Tank Mounted
AIR COMPRESSOR
Model No.
919.167242
Safety Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Troubleshooting
Repair
Parts
CAUTION;
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears,
Roebuck
and Co., Hoffman
Estates,
IL 60179
U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D30085
Rev. 4
9/3/04

Advertisement

loading

Summary of Contents for Craftsman 919.167242

  • Page 1 • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION; Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D30085 Rev. 4 9/3/04...
  • Page 2 FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge, Contact your nearest Sears Service...
  • Page 3: Glossary

    ___o]][I I[o,] - "P'_,_ -'_n n l Model N o. 919-167242 Max. Developed Running HP Bore 1.875" Stroke 1.25" Voltage-Single Phase 120V Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig Refer to Glossary for abbreviations.
  • Page 4 Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. I: V;YJ;I;1m] WARNING: Risk of explosion or fire How To Prevent It What Could Happen It is normal for electrical contacts...
  • Page 5: Accessories

    I: V;_,_;l ; 1m] WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. How To Prevent It What Could Happen Failure to properly drain condensed Drain tank daily or after each use.
  • Page 6 I-" F._'.4.-1 ml WARNING: Risk of Electrical Shock How To Prevent It What Could Happen Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with properly it may cause electric...
  • Page 7 : V;_,J;l ; 1m_ WARNING: Risk of Burns How To Prevent It What Could Happen Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 I-"V-'_J-'_-'| m] WARNING: Risk of Unsafe Operation How To Prevent It What Could Happen Review and understand all instructions unsafe operation of your air compressor and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others.
  • Page 9: Duty Cycle

    Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    Contents of Carton It will be necessary to brace or support 1 - Air Compressor one side of the outfit when Wheels installing the wheels because the 2 - Shoulder Bolts, 3/8-16 compressor will have a tendency to tip over. 2 - Hex Nuts, 3/8-16 Install one shoulder bolt and one 2 - Molded Foot Bumpers...
  • Page 11 HOW TO SET UP YOUR IMPORTANT: The outlet being used must be installed and grounded in UNIT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a clean, has the same configuration dry and well ventilated area.
  • Page 12: Operation

    Extension Cords Voltage and Circuit Protection Refer to the specification chart for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit requirements. cords will cause voltage to drop resulting in power loss to the motor Risk of Unsafe and overheating.
  • Page 13 Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. On/Auto/Off Pressure Switch Switch Outlet...
  • Page 14 Drain Valve: The drain valve is Before Starting located at the base of the air tank Break-in Procedure and is used to drain condensation the end of each use. Risk of Unsafe Operation. Serious damage may result if the following break-in instructions are not closely followed.
  • Page 15 How to Start: Before Each Start-Up: Place On/Auto/Off lever to Turn the On/Auto/Off lever to "OFF" and close air regulator. "AUTO" and allow tank pressure to build. Motor will stop when Pull regulator knob out, turn tank pressure reaches "cut-out" counterclockwise until it stops.
  • Page 16 Customer Responsibilities Before Daily or each after each Check Safety Valve • Drain Tank • To Drain Tank Risk of Unsafe Operation. Unit Set the On/Auto/Off lever to cycles automatically when power is "OFF" and unplug unit. on. When servicing, you may be Pull the regulator knob out and exposed to voltage sources, turn counterclockwise...
  • Page 17: Maintenance

    ALL MAINTENANCE AND REPAIR Unscrew the check valve (turn OPERATIONS NOT LISTED MUST counterclockwise) using a socket wrench. BE PERFORMED BY TRAINED SERVICE TECHNICIAN. Make sure the valve disc moves freely inside the check valve and Risk of Unsafe the spring holds the disc in the Operation.
  • Page 18 NOTE: Arrow indicates flow of air. To Replace Regulator Make sure it is pointing in the Release all air pressure from air direction of air flow. tank. See "To Drain Tank" in the Maintenance section. Release all air pressure from air tank.
  • Page 19 Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 20 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated aressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
  • Page 21 PROBLEM CAUSE CORRECTION Motor will not Fuse blown, circuit breaker Check fuse box for blown run. tripped. fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
  • Page 22 Air Compressor Model Number 919.167242 D30085 22-ENG...
  • Page 23 D20114 Safety Valve • 21 CAC-1254 Isolator LA-3027 Label -- Drain Tank LA-3266 Label -- Warning LA-3069 Label -- Craftsman D30077 Label -- Performance • 28 SSF-621 Screw, #8-18 x .625 (2) D23627 Label -- Tool Application D25730 Grip 23-ENG...
  • Page 24 I_lJ Lv4 d I m]V_'_[dJ]_ Air Compressor Model Number 919.167242 Torque 26o32 ft.qbs. 2_,/2 315_385 in.4bs. Torque D30085 24-ENG...
  • Page 25 Air Compressor Model Number 919.167242 Part Number Description • SSG-8169 "O" Ring ÷x BSF-3147 Screw 3/8-16 UNC Hex ÷> Rod Assembly ÷+ D21127 Screw #10-24 x .563 ÷ Connecting Rod Cap ÷+ Pre-Formed Compression Ring ÷ Endbell Assembly D25735 Shroud (left) •...
  • Page 26 GARANTIA TOTAL DE UN AI_IO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra, Sears, a su opci6n, Io reparara o reemplazara sin costo alguno.
  • Page 27 [o..]uy;1 _,]::[o]I_,] : :11 =[,.-..] -..,1=[o-] I=1 [o-7;Io-] [o]_I=[,.-.,] Modelo N ° 919.167242 MAx. HP desarrollado 1,5 HP Potencia de trabajo DiAmetro interior 1,875" (47,6 mm) Carrera 1,25" (31,8 mm) 120V Voltaje-corriente manof_sica Circuito minimo requerido Tipo de fusibleAcci6n retardada Capacidad de aire en el tanque 15 Galones (56,8 litros)
  • Page 28 GUARDE ESTAS INSTRUCCIONES La operaci6n o el mantenimiento inadecuados de este producto podrian ocasionar serias lesiones y da_os a la propiedad. Lea y comprenda todas las advertencias instrucciones de funcionamiento antes de utilizar este equipo. I ".] =1 ! [_];[o] ADVERTENCIA: Riesgo de Explosi6n...
  • Page 29 I"..,1 =1 ! [,_-"[,] ADVERTENCIA: Riesgo Explosi6n Tanque de aire: las siguientes condiciones podrfan, causar el debilitamiento del tanque, determinar su explosi6n violenta, da_os a la propiedad o serias lesiones. puede occurrir cbmo prevenirlo Drenaje inadecuado del agua condensada Drene el tanque diariamente o despu_s de en el tanque, siendo la causa del bxido que...
  • Page 30 I'.,] _ ! [_-'[,,] ADVERTENCIA: Riesgo de choque eldctrico qud puede occurrir cbmo prevenirlo Su compresor de aire esta accionado Jamas opere el compresor a la intemperie electricidad. Como cualquier otto dispositivo cuando esta Iloviendo o en condiciones electrico impulsado electricamente, si no se Io humedad.
  • Page 31 ADVERTENCIA: Riesgo de Quemaduras qud puede occurrir cbmo prevenirlo Jam_s toque partes de metal expuestas en el Tecar el metal expuesto tal come el cabezal compresor durante o inmediatamente despues del compresor o los tubes de salida del de la operaci6n, el compresor permanecer_ escape, puede ecasionarle...
  • Page 32 Id ::l! [_-'[,] ADVERTENCIA: Riesgo de Operaci6n Insegura cbmo prevenirlo clud puede occurrir La operacion insegura de su compresor Revise y comprenda todas las instruociones y aire podria ocasionarle serias lesiones o la advertencias contenidas en este manual. muerte a usted u otros. Familiaricese con los m_todos de operaci6n y control del compresor...
  • Page 33 Presi6n minima de corte: Cuando el Familiaricese con los siguientes t6rminos, motor est_ apagado, la presi6n del tanque antes de operar la unidad: de aire baja a medida que usted continOa CFM: (Cubic feet per minute) Pies cL_bicos usodo su accesorio. Cuando la presi6n por minuto.
  • Page 34 Contenido del embalaje Ser_i necesario sujetar o soportar Compresor de aire un lado del equipo cuando se instalen Ruedas las ruedas porque el compresor tendra tendencia a volcarse. Bulones de tope, 3/8 - 16 Instale un bul6n de tope y una tuerca Tuerca hexagonal, 3/8 - 16 pot cada rueda.
  • Page 35 COMO PREPARAR LA UNIDAD Asegt_rese de que el tomacorriente que serA utilizado tenga la misma configuraci6n que el enchufe de Ubicaci6n del compresor de aire conexi6n a tierra. NO UTILICE UN Ubique al compresor de aire en una zona ADAPTADOR. Ver figura.
  • Page 36 Cables de extensi6n el_ctrica Protecci6n del voltaje y del circuito No se recomienda la utilizaci6n de cables Acerca del voltaje y la minima cantidad de de extensi6n el_ctrica. El uso de cables circuitos requeridos, refi@ase al cuadro de especificaciones. de extensi6n el_ctrica originarA una caida de tensi6n, Io que determinarA una Riesgo de p@dida de potencia del motor asf como...
  • Page 37 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 38 Wilvula de drenaje: La vAIvula de drenaje Antes de poner en marcha se encuentra ubicada sobre la base del Procedimiento para el asentamiento tanque de aire y se usa para drenar la condensaci6n al fin de cada uso Riesgo de Operacibn Insegura.
  • Page 39 Antes de cada puesta en marcha: C6mo poner en marcha: Coloque el interruptorOn/Auto/Off en la Mueva la palanca On/Auto/Off a la posicidn "OFF" y cierre el regulador de posicidn "AUTO" y deje que se aire. incremente la presi6n del tanque. El motor se detendra una vez alcanzado el Tire de la perilla del regulador, gire en valor de presidn "de corte"...
  • Page 40 Responsabilidades del cliente Antes Diariarnente cada oluegode cadaLLSO Verifique la v_lvula de seguridad • Drenaje del tanque • C6mo drenar el tanque Riesgo de Operacibn Apagar la unidad colocando Insegura: La unidad arranca interruptor en On/Auto/OFF automaticamente cuando esta "OFF". enchufada.
  • Page 41 TODO TIPO DE MANTENIMIENTO Desenrosque la v41vula reguladora (gire OPERACIONES DE REPARACION NO en sentido antihorario) utilizando una MENCIONADOS, DEBER,&.NSER Ilave tubular. EFECTUADOS POR PERSONAL TI_CNICO ESPECIALIZADO. Aseg0rese que el disco de la valvula se mueva libremente dentro de la v&lvula reguladora y que el resorte sujete al Riesgo de Operaci6n...
  • Page 42 NOTA: La flecha indica el sentido del Para reemplazar el regulador flujo del aire. AsegOrese que este apuntando a la direcci6n en la que fluye Libere toda la presi6n del aire del el aire. tanque. Vea "Drenaje del tanque" en la secci6n "Mantenimiento".
  • Page 43 Antes de guardar su compresor de aire, Riesgo de Explosi6n. El aseg0rese de hacer Io siguiente: agua se condensa dentro del tanque de Revise la secci6n "Mantenimiento" aire. Si no se drena, ella corroera de las pAginas precedentes y ejecute debilitando la paredes del tanque de el mantenimiento...
  • Page 44 [e'II_:q I .] =11 .] V:Te-]_'_iIo_o] I.] =11 : .1 ;_[o) :] q =1 L'_ P ':T.'] Riesgo de Operacibn Insegura: La unidad arranca automaticamente cuando esta enchufada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles.
  • Page 45 PROBLEMA CORRECClON CAUSA Si hubiese una caida excesiva de La lectura de la Es normal que ocurra algt_n presi6n durante el uso del presi6n sobre un descenso en la presi6n. accesorio, ajuste el regulador de man6metro acuerdo alas instrucciones de la viene equipado secci6n Operaci6n.
  • Page 46 CORRECClON PROBLEMA CAUSA El motor no Veriflque la caja de fusibies observando Fusible fundido; interruptor funciona. automatico del circuito disparado. laexistencia de fusibles fundidos y sustituyalos en caso de necesidad. Restablezcael interruptor autom&tico. No use unfusible o interruptorautomatico con valores que excedan los especificados para la rama de su circuito.
  • Page 47: Repair Protection Agreements

    Repair Protection Agreements Reparaciones Congratulations on making a smart Fe/icitacfenes por hacer una compra purchase. Your new Craftsman c_product intefigente. Su nueva unidad Craftsman ® esta designed and manufactured for years of diseflada y fabricada para aflos de operacion dependable operation.
  • Page 48 Your Home For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner's manuals that you need to do-it-yourself, For Sears professional installation of home appliances and items like garage door openers and water heaters, 1-800-4-MY-HOME...