Connections
+ Before making
connections,
turn off all the equipment.
+ Plugs should be firmly inserted;
poor connection
could cause noise.
+ 'l_) unplug
a cord, be sure to grasp its plug and pull it out.
+ Connect
the power cord after having finished all other connections.
+ Refer also to the user manual
of each piece of equipment.
Video signals
The following
signals can be input to this Monitor:
+ VIDEO A and VIDEO B terminals
accept -- NTSC, PAL M, and PAL IN signals.
+ GOMPONENT/IqGB
B terminals
accept -- 480i, 576i, 480p, 576p, 720/60p,
1080/50i,
and 1080/60i
(1035/60i)
signals. (You
need to set "RGB/COMPO."
to "COMPO."
on the menu (see page 22).
Computer signals (Preset)
This Monitor
has 18 preset video modes for the most popular
industrial
standard,
and the signals of the following
image
resolutions
can be input to the RGB input terminals.
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Signal
name
PC98
VGA400-70
VGA480-60
VGA480-72
VGA480-75
WVGA -60
MAC13"
SVGA-56
SVGA-60
SVGA-72
SVGA-75
XGA -60
XGA -70
XGA -75
XGA -85
XGA+-75
RGB15K-60
RGB15K-50
Screen resolution
Horizontal
Vertical
640
400
640
400
640
480
640
480
640
480
852
480
640
480
800
600
800
600
800
600
800
600
1024
768
1024
768
1024
768
1024
768
1152
864
Horizontal
Frequency
(kHz)
24.8
31.5
31.5
31.7
37.5
31.7
35.0
35.2
37.9
48.1
46.9
48.4
56.5
60.0
68.7
67.5
15.7
15.6
Vertical
Frequency
(Hz)
56.4
70.1
59.9
72.8
75.0
60.3
66.7
56.3
60.3
72.2
75.0
60.0
70.1
75.0
85.0
75.0
59.9
50.0
Scan system
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
Non-interlace
]interlace
]interlace
Notes:
+ When a signal other than listed above is input,
a part of the screen may become void or an unnecessary
picture may appear.
+ Signals, though
they are within the acceptable
range of frequencies,
may not be displayed
normally, depending
on the signal
type.
+ Depending
on the connected
equipment,
the Monitor
may not be compatible
with composite
sync (Cs) or G on sync signals.
+ When a preset mode signal is input, the vertical frequency
displayed
on the screen will have an "*" shown at its right top
position.
+ When the No. 6 signal is input, change the aspect ratio to "FULL" with the ASPECT button
(page 15) on the remote control or
from the "FUNCTION
SELECT" menu (page 21 ).
+ When No. 8 to No. 16 signals are input, thin lines may become obscure for their signal frequencies
are higher than the screen
resolution.
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm-v42ug

Table of Contents