STYLUS 800 Sewice Manual
CR MOTOR Removal
3.2.5.5
[Step 1] Remove the printer mechanism. (Refer to section 3.2.4.)
[Step 2] Remove the tension spring and take thetimingbeltout of the CRmotordrive pulley.
[Step3] Remove 3 screws (CP(P2) screw (M3 x 10) x 3) that fixing the CR motor to the CR motor
holder plate, and remove the CR motor.
Rev. A
Figure 3-12. CR MOTOR Removal
Disassembly and Assembiy
CP(P2)(M3XIO)
3-13