3. Use a
" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
No appliance
below cooktop
A
B
C
D
E
F
G
H
I
A. Manifold entrance
B. Gas pressure regulator
C. Use pipe-joint
compound.
D. Adapter (must have ½"
male pipe thread)
E. Flexible connector
F. Adapter
G. Use pipe-joint
compound.
H. Manual gas shutoff
valve
I. ½" or ¾" gas pipe
4. Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop base and in a position
where you can reach the regulator access cap.
A
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Up arrow. Regulator must be installed with
arrow pointing up to cooktop bottom.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn on the pipe
when tightening fittings.
Wall oven installed below cooktop
A
B
C
D
E
F
G
H
I
J
K
A. Manifold entrance
B. " elbow
C. Use pipe-joint compound.
D. Adapter (must have
" male pipe
thread)
E. Flexible connector (pass through wall
between cabinets)
F. Adapter (must have
" male pipe
thread)
G. Use pipe-joint compound.
H. Appliance pressure regulator
(supplied)
I. ½" or ¾" gas pipe
J. Manual gas shutoff valve
K. ½" or ¾" gas pipe
B
C
D
Use only pipe-joint compound made for use with Natural and LP
gas.
Do not use TEFLON
®
tape. You will need to determine the fittings
required depending on your installation.
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
3. Remove surface burner caps and grates from parts package.
Align notches in burner caps with pins in burner base. Burner
caps should be level when properly positioned. If burner caps
are not properly positioned, surface burners will not light.
Place burner grates over burners and caps.
A
A. Igniter electrode
B. Burner cap
C. Burner base
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
4. Plug into a grounded 3 prong outlet.
B
B
C
7