Checking Temperature Status; System Message Log - HP SN3000B Troubleshooting Manual

Troubleshooting and diagnostics guide
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

10

System message log

Checking temperature status

1. Connect to the switch and log in as admin.
2. Enter the tempShow command:
System message log
The system message log, or RASLog, feature enables messages to be saved across power cycles
and reboots.
The Brocade DCX, DCX 8510 family, and DCX-4S enterprise-class platforms maintain the same
RASlog for each of the two CP blades. Since all RASlog messages are routed to the Active CP, the
message CPU ID is added as part of the RASlog message attribute. RASlog message attribute SLOT
is defined to identify the CPU that generated the message.
For example, in the following message the identifier SLOT 6 means the message was generated
from the slot 6 blade main CPU:
and the identifier SLOT 6/1 means the message was generated from slot 6 blade Co-CPU.
Since RASlog supports Virtual Fabrics and logical switches, the FID (Fabric ID) displays on every
RASlog message to identify the source of the logical switch that generates the message.
100
If any of the power supplies show a status other than OK, consider replacing the power supply
as soon as possible. For certain switch models, the OEM serial ID data displays after each
power supply status line.
switch:admin> tempshow
Sensor
State
ID
=================================================
1
Ok
2
Ok
3
Ok
Information displays for each temperature sensor in the switch.
The possible temperature status values are:
OK—Temperature is within acceptable range.
FAIL—Temperature is outside of acceptable range. Damage might occur.
Refer to the hardware reference manual for your switch to determine the normal temperature
range.
2001/01/07-04:03:00, [SEC-1203], 2,SLOT 6 | FFDC | CHASSIS, INFO, C08_1, Login
information: Login successful via TELNET/SSH/RSH. IP Addr: 192.168.38.2050
2001/01/07-04:03:00, [SEC-1203], 2, SLOT 6/1 , | FFDC | CHASSIS, INFO, C08_1,
Login information: Login successful via TELNET/SSH/RSH. IP Addr:
192.168.38.2050
Centigrade
Fahrenheit
28
82
16
60
18
64
Fabric OS Troubleshooting and Diagnostics Guide
53-1002150-02