Setting The System Option Modes; Configuring The Fibre Channel Ports; Installing And Configuring The Host; Loading The Operating System And Software - HP StorageWorks P9000 Configuration Manual

Hp storageworks p9000 configuration guide (av400-96380, may 2011)
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 20 Host group modes (options) Solaris (continued)
Host
Group
Mode
Function
13
SIM report at link failure
Select HMO 13 to enable SIM notification
when the number of link failures detected
between ports exceeds the threshold.
22
Veritas Cluster Server
When a reserved volume receives a Mode
Sense command from a node that is not
reserving this volume, the host will receive the
following responses from the storage system:
ON: Normal response
OFF (default): Reservation Conflict
NOTE:
CAUTION:
configured is disruptive and requires the server to be rebooted.

Setting the system option modes

The HP service representative sets the system option mode(s) based on the operating system and
software configuration of the host. Notify your HP representative if you install storage agnostic
software (such as backup or cluster software) that might require specific settings.

Configuring the Fibre Channel ports

Configure the disk array Fibre Channel ports by using Command View Advanced Edition or Remote
Web Console. Select the settings for each port based on your SAN topology. Use switch zoning
if you connect different types of hosts to the array through the same switch.

Installing and configuring the host

This section explains how to install and configure Fibre Channel adapters (FCAs) that connect the
host to the disk array.

Loading the operating system and software

Follow the manufacturer's instructions to load the operating system and software onto the host.
Load all OS patches and configuration utilities supported by HP and the FCA manufacturer.
78
Solaris
When HMO 22 is ON, the volume status
(reserved/non-reserved) will be checked
more frequently (several tens of msec per
LU).
When HMO 22 is ON, the host OS will
not receive warning messages when a
Mode Select command is issued to a
reserved volume.
There is no impact on the Veritas Cluster
Server software when HMO 22 is OFF.
Set HMO 22 to ON when the software is
experiencing numerous reservation
conflicts.
Set HMO 22 to ON when Veritas Cluster
Server is connected.
Changing host group modes for ports where servers are already installed and
Default
Comments
Inactive
Optional This mode is
common to all host
platforms.
OFF
NOTE:
Note:HMO 22
can be changed while the
host is online. However
I/O activity may be
affected when it is being
changed. It is
recommended to stop the
host IO on the port where
you want to change the
HMO 22 setting.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500P9500

Table of Contents