Configuring Disk Array Devices; Partitioning The Devices - HP StorageWorks P9000 Configuration Manual

Hp storageworks p9000 configuration guide (av400-96380, may 2011)
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

3.
Verify that the system recognizes the disk array partitions by viewing the /proc/partitions
file.
Example
#cat /proc/partitions
major minor #blocks
8
0
8
1
8
2
8
16
8
17
8
18
8
32
8
33
8
34
8
48
8
49
8
50
8
64
8
65
8
66
8
80
8
81
8
82
8
96
8
97
104
0
104
1
104
2
104
3
In the previous example, the "sd" devices represent the P9000 disk partitions and the "cciss"
devices represent the internal hard drive partitions on an HP Proliant system.

Configuring disk array devices

Disks in the disk array are configured using the same procedure for configuring any new disk on
the host. This includes the following procedures:
1.
"Partitioning the devices" (page 73)
2.
"Creating the file systems" (page 74)
3.
"Creating the mount directories" (page 74)
4.
"Creating the mount table" (page 74)
5.
"Verifying file system operation" (page 75)
Creating scripts to configure all devices at once could save you considerable time.

Partitioning the devices

In a Linux environment, one LUN can be divided into a maximum of four primary partitions (using
fdisk) or maximum of one extended partition.
After the device parameters have been set, the next step is to set the partitions. To partition the
devices:
1.
Enter fdisk/dev/device_name.
Example
# fdisk/dev/sda
2.
Select p to display the present partitions.
3.
Select n to make a new partition. You can make up to four primary partitions or you can make
one extended partition. The extended partition can be divided into a maximum of 1 1 logical
partitions, which can be assigned partition numbers from 5 to 15.
name
7211520
sda
7181087
sda1
28272
sda2
7211520
sdb
7181087
sdb1
28272
sdb2
7211520
sdc
7181087
sdc1
28272
sdc2
7211520
sdd
7181087
sdd1
28272
sdd2
7211520
sde
7181087
sde1
28272
sde2
7211520
sdf
7173022
sdf1
32130
sdf2
7211520
sdg
7173022
sdg1
17776560 cciss/c0d0
257024
cciss/c0d0p1 1
1048560
cciss/c0d0p2 2
16470960 cciss/c0d0p3 168193 352166 4166736...
rio
rmerge rsect
1
3
8
0
0
0
0
0
0
1
3
8
0
0
0
0
0
0
1
3
8
0
0
0
0
0
0
1
3
8
0
0
0
0
0
0
1
3
8
0
0
0
0
0
0
1
3
8
0
0
0
0
0
0
1
3
8
0
0
0
168200 352184 4166792...
3
8
3
16
Configuring disk array devices
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500P9500

Table of Contents